Line-voltage control based on wayside energy storage systems for tramway networks

F Ciccarelli, D Iannuzzi, K Kondo… - IEEE Transactions on …, 2015 - ieeexplore.ieee.org
This paper presents a control strategy for the power flow management of a wayside energy
storage system based on a supercapacitor technology installed in a tramway network. The …

A new integrated hybrid power quality control system for electrical railway

S Hu, Z Zhang, Y Chen, G Zhou, Y Li… - IEEE Transactions …, 2015 - ieeexplore.ieee.org
This paper presents an integrated hybrid railway power quality control system (HRPQC) to
deal with the power quality problems in the electrical railway supply system. The prominent …

A power factor-oriented railway power flow controller for power quality improvement in electrical railway power system

S Hu, B Xie, Y Li, X Gao, Z Zhang, L Luo… - IEEE Transactions …, 2016 - ieeexplore.ieee.org
Focusing on the freight-train dominant electrical railway power system (ERPS) mixed with ac-
dc and ac-dc-ac locomotives (its power factorε [0.70, 0.84]), this paper proposes a power …

Modern power quality improvement devices applied to electric railway systems

M Brenna, HJ Kaleybar, F Foiadelli… - … on Harmonics & …, 2022 - ieeexplore.ieee.org
Electric railway supplying systems (ERSSs) as one of the foremost and critical loads of the
grid have been faced with power quality (PQ) issues all around the world. Due to the various …

A New Railway Power Flow Control System Coupled With Asymmetric Double LC Branches

S Hu, Z Zhang, Y Li, L Luo, P Luo, Y Cao… - … on Power Electronics, 2014 - ieeexplore.ieee.org
Facing the challenges of power quality problems and excessive neutral sections of
conventional two-phase electric railway supply system, the way of adopting railway static …

A comprehensive study for the power flow controller used in railway power systems

S Hu, S Li, Y Li, O Krause, F Zare - IEEE Transactions on …, 2017 - ieeexplore.ieee.org
Essential imbalance and fluctuation of the mobile train load draw some problems, eg, three-
phase unbalance, reactive power, voltage and load fluctuation, harmonics, etc. in both …

Cascaded dual-buck AC–AC converter with reduced number of inductors

AA Khan, H Cha, JW Baek, J Kim… - IEEE Transactions on …, 2016 - ieeexplore.ieee.org
This paper proposes a new type of cascaded ac-ac converter with phase-shift control and
reduced number of inductors. It can attain high voltage levels by using standard low-voltage …

An active railway power quality compensator for 2× 25kV high-speed railway lines

HJ Kaleybar, HM Kojabadi, M Brenna… - … on Environment and …, 2017 - ieeexplore.ieee.org
The AC 2× 25 kV power supply system is a widespread solution in high-speed railway
networks. Owing to the operation of high-power trains in these systems, the 4Q converter …

A novel single-phase cascaded multilevel AC-AC converter without commutation problem

S Kim, HG Kim, H Cha - 2014 IEEE Energy Conversion …, 2014 - ieeexplore.ieee.org
This paper presents a novel cascaded multilevel PWM ac-ac converter that can solve
commutation problem. By cascading the single-phase PWM ac-ac converter that uses basic …

Calculation of the Voltage Unbalance Factor for 25kV-50Hz Railway Substations

D Flumian, P Ladoux, E Sarraute - 2022 20th International …, 2022 - ieeexplore.ieee.org
This paper presents a method to determine the voltage unbalance factor for a 25kV/50Hz
railway substation taking into account the power drawn by the trains. In order to correctly …