Corrosion degradation and prevention by surface modification of biometallic materials

R Singh, NB Dahotre - Journal of Materials Science: Materials in Medicine, 2007 - Springer
Metals, in addition to ceramics and polymers, are important class of materials considered for
replacement of non-functional parts in the body. Stainless steel 316, titanium and titanium …

Modular neck femoral stems

H Krishnan, SP Krishnan, G Blunn… - The bone & joint …, 2013 - boneandjoint.org.uk
Following the recall of modular neck hip stems in July 2012, research into femoral
modularity will intensify over the next few years. This review aims to provide surgeons with …

[图书][B] Bone mechanics handbook

SC Cowin - 2001 - taylorfrancis.com
This second edition of the Bone Mechanics Handbook summarizes the current
understanding of bone mechanics with comprehensive coverage of the histology …

Adverse local tissue reaction arising from corrosion at the femoral neck-body junction in a dual-taper stem with a cobalt-chromium modular neck

HJ Cooper, RM Urban, RL Wixson, RM Meneghini… - JBJS, 2013 - journals.lww.com
Background: Femoral stems with dual-taper modularity were introduced to allow additional
options for hip-center restoration independent of femoral fixation in total hip arthroplasty …

Modular titanium alloy neck adapter failures in hip replacement-failure mode analysis and influence of implant material

TM Grupp, T Weik, W Bloemer, HP Knaebel - BMC musculoskeletal …, 2010 - Springer
Background Modular neck adapters for hip arthroplasty stems allow the surgeon to modify
CCD angle, offset and femoral anteversion intraoperatively. Fretting or crevice corrosion …

Is increased modularity associated with increased fretting and corrosion damage in metal-on-metal total hip arthroplasty devices?: a retrieval study

GB Higgs, JA Hanzlik, DW MacDonald, JL Gilbert… - The Journal of …, 2013 - Elsevier
This retrieval study documents taper damage at modular interfaces in retrieved MOM THA
systems and investigates if increased modularity is associated with increased fretting and …

Corrosion of a hip stem with a modular neck taper junction: a retrieval study of 16 cases

AM Kop, E Swarts - The Journal of arthroplasty, 2009 - Elsevier
Since the early 1990s, there has been a dramatic increase in modular total hip designs
ranging from a stem with a proximal taper and modular head, to a distal stem, double taper …

Fracture of a modular femoral neck after total hip arthroplasty: a case report

G Wright, S Sporer, R Urban, J Jacobs - JBJS, 2010 - journals.lww.com
Discussion Modular hip systems have gained popularity as they offer the surgeon the
potential to restore normal hip biomechanics with the ability to independently adjust offset …

In vitro corrosion testing of modular hip tapers

JR Goldberg, JL Gilbert - … : An Official Journal of The Society for …, 2003 - Wiley Online Library
The in vivo fretting behavior of modular hip prostheses was simulated to determine the
effects of material combination and a unique TiN/AlN coating on fretting and corrosion at the …

Proximal component modularity in THA—at what cost?: an implant retrieval study

AM Kop, C Keogh, E Swarts - Clinical Orthopaedics and Related …, 2012 - journals.lww.com
Background While modular femoral heads have been used in THA for decades, a recent
innovation is a second neck-stem taper junction. Clinical advantages include intraoperative …