Lab-on-skin: a review of flexible and stretchable electronics for wearable health monitoring

Y Liu, M Pharr, GA Salvatore - ACS nano, 2017 - ACS Publications
Skin is the largest organ of the human body, and it offers a diagnostic interface rich with vital
biological signals from the inner organs, blood vessels, muscles, and dermis/epidermis. Soft …

Use of central venous oxygen saturation to guide therapy

KR Walley - American journal of respiratory and critical care …, 2011 - atsjournals.org
The use of pulmonary artery catheters has diminished, so that other technologies are
emerging. Central venous oxygen saturation measurement (ScvO2) as a surrogate for mixed …

Early goal-directed therapy in severe sepsis and septic shock: insights and comparisons to ProCESS, ProMISe, and ARISE

HB Nguyen, AK Jaehne, N Jayaprakash, MW Semler… - Critical Care, 2016 - Springer
Prior to 2001 there was no standard for early management of severe sepsis and septic
shock in the emergency department. In the presence of standard or usual care, the …

Sympathetic overstimulation during critical illness: adverse effects of adrenergic stress

MW Dünser, WR Hasibeder - Journal of intensive care …, 2009 - journals.sagepub.com
The term ''adrenergic''originates from ''adrenaline''and describes hormones or drugs whose
effects are similar to those of epinephrine. Adrenergic stress is mediated by stimulation of …

Continuous central venous and pulmonary artery oxygen saturation monitoring in the critically ill

K Reinhart, HJ Kuhn, C Hartog, DL Bredle - Intensive care medicine, 2004 - Springer
Objective To compare the course of continuously measured mixed and central venous O 2
saturations in high-risk patients and to evaluate the impact of various factors that might …

Severe sepsis and septic shock: review of the literature and emergency department management guidelines

HB Nguyen, EP Rivers, FM Abrahamian… - Annals of emergency …, 2006 - Elsevier
Severe sepsis and septic shock are as common and lethal as other acute life-threatening
conditions that emergency physicians routinely confront such as acute myocardial infarction …

[PDF][PDF] Trends but not individual values of central venous oxygen saturation agree with mixed venous oxygen saturation during varying hemodynamic conditions

MH Dueck, M Klimek, S Appenrodt, C Weigand… - …, 2005 - jvsmedicscorner.com
Background: Previous studies found contradictory results re-garding the question whether
mixed venous oxygen saturation (SvO2) and central venous oxygen saturation (ScvO2) are …

Lack of equivalence between central and mixed venous oxygen saturation

LS Chawla, H Zia, G Gutierrez, NM Katz, MG Seneff… - Chest, 2004 - Elsevier
Study objective: We compared paired samples of central venous O 2 saturation (Scv o 2)
and mixed venous O 2 saturation (Sv o 2) to test the hypothesis that Scv o 2 is equivalent to …

The influence of early hemodynamic optimization on biomarker patterns of severe sepsis and septic shock

EP Rivers, JA Kruse, G Jacobsen, K Shah… - Critical care …, 2007 - journals.lww.com
Background: Despite abundant experimental studies of biomarker patterns in early severe
sepsis and septic shock, human data are few. Further, the impact of the severity of global …

[图书][B] Intensive care nursing: a framework for practice

P Woodrow - 2018 - taylorfrancis.com
Especially written for qualified nurses working in intensive care units, this comprehensive
text has been developed to be as accessible as possible. This fourth edition has been …