Experimental and numerical study on the heat transfer performance of the radiant floor heating condenser with composite phase change material

T Jiang, C Zheng, S You, H Zhang, Z Wu… - Applied Thermal …, 2022 - Elsevier
Traditional hot-water ASHP systems have disadvantage of low energy efficiency due to the
requirement of secondary heat exchange. To maintain the stability of indoor air temperature …

Thermal performance analysis of a new refrigerant-heated radiator coupled with air-source heat pump heating system

S Shao, H Zhang, S You, W Zheng, L Jiang - Applied Energy, 2019 - Elsevier
Air-source heat pump (ASHP) is considered to be one of the most energy conservation
heating system in the areas without district heating. To improve the performance of the …

Thermal comfort in residential buildings using bimetal radiator heating vs. floor heating terminals

H Yan, L Yang, M Dong, B Hu, Z Sun, F Shi… - Journal of Building …, 2022 - Elsevier
Bimetal radiator heating terminals (BRH) have gradually replaced the traditional cast-iron
radiator and have been widely used in urban residential buildings in cold areas of China …

Experimental testing of phase change materials in a warm-summer humid continental climate

M Sinka, D Bajare, A Jakovics, J Ratnieks… - Energy and …, 2019 - Elsevier
The construction industry (and buildings) is one of the largest energy consuming and CO 2
emitting sectors in the world. To counter this, more lightweight structures are being used and …

On the procedure of draught rate assessment in indoor spaces

D Markov, N Ivanov, G Pichurov, M Zasimova… - Applied Sciences, 2020 - mdpi.com
Featured Application In case the ventilation system design leads to low-frequency high-
amplitude air velocity pulsations, strong time variation of the draught rate (DR) index may …

Numerical and experimental investigations on heat transfer performance of the refrigerant-heated radiator

S Shao, H Zhang, W Zheng, S You, Y Wang - Applied Thermal Engineering, 2020 - Elsevier
The refrigerant-heated radiator (RHR) has been proved to be an efficient refrigerant-heated
terminal of the air-source heat pump (ASHP) for space heating. The evaluation and analysis …

In-situ measurements of hemp-lime insulation materials for energy efficiency improvement

M Sinka, D Bajare, S Gendelis, A Jakovics - Energy Procedia, 2018 - Elsevier
Reduction of the CO 2 emissions in the atmosphere is one of the goals set forth by the
European Union, hence various directives have been adopted, such as the European …

Performances investigations on thermal characteristics of a novel direct-condensation convective-radiant heating panel: An experimental and numerical study

C Xu, S Shao - Applied Thermal Engineering, 2024 - Elsevier
The direct-condensation heating panel integrated with air source heat pump (ASHP) system
was previously proposed and proven to be an effective heating method in winter, but the …

Experimental investigation of an air source heat pump with multigroup heat pipe radiators

S Xu, J Niu, G Ma - Solar Energy, 2023 - Elsevier
As a clean and sustainable electrified heating technology, air source heat pump (ASHP) has
been widely used in household in China. However, some problems occurred with the …

Thermal comfort evaluation of natural convective-radiant evaporator for air conditioning

H Zhang, R Zhao, M Tao… - Indoor and Built …, 2024 - journals.sagepub.com
The radiant systems come to the fore due to energy saving potential and good integration.
The effect of different forms of cold surfaces on human thermal comfort is focused on its …