An overview of the tribological and mechanical properties of PEEK and CFR-PEEK for use in total joint replacements

S Arevalo, C Arthurs, MIE Molina, L Pruitt… - Journal of the Mechanical …, 2023 - Elsevier
Abstract Poly-ether-ether-ketone (PEEK) and PEEK composites are outstanding candidates
for biomedical applications, such as orthopedic devices, where biocompatibility and …

Metallosis after knee replacement: a review

I Sahan, K Anagnostakos - Archives of orthopaedic and trauma surgery, 2020 - Springer
Introduction Although metallosis is a well-known complication after total hip arthroplasty,
little is known about this phenomenon after total (TKA) or unicompartmental knee …

Wear in total knee arthroplasty—just a question of polyethylene? Metal ion release in total knee arthroplasty

JP Kretzer, J Reinders, R Sonntag, S Hagmann… - International …, 2014 - Springer
Purpose Biological reactions against wear particles are a common cause for revision in total
knee arthroplasty. To date, wear has mainly been attributed to polyethylene. However, the …

[HTML][HTML] Metallosis: a diagnosis not only in patients with metal-on-metal prostheses

CA Oliveira, IS Candelária, PB Oliveira… - European Journal of …, 2015 - Elsevier
Although the real actual incidence of metallosis is unknown, it is described as a rare
diagnosis with a 5% estimated incidence in the hip prosthetic replacements. The adoption of …

The estimated lifetime risk of revision after primary knee arthroplasty is influenced by age, sex, and indication

LZ Yapp, ND Clement, M Moran… - The Bone & Joint …, 2022 - boneandjoint.org.uk
Aims The aim of this study was to assess factors associated with the estimated lifetime risk of
revision surgery after primary knee arthroplasty (KA). Methods All patients from the Scottish …

Silicone and pyrocarbon artificial finger joints

FA Alnaimat, HA Owida, A Al Sharah… - Applied Bionics and …, 2021 - Wiley Online Library
Artificial finger joint design has been developed through different stages through the past.
PIP (proximal interphalangeal) and MCP (metacarpophalangeal) artificial finger joints have …

A minimum 5-year follow-up of an oxidized zirconium femoral prosthesis used for total knee arthroplasty

JK Hofer, KA Ezzet - The Knee, 2014 - Elsevier
Background Bearing surface wear remains a potential concern amongst younger patients
undergoing total knee arthroplasty (TKA). Because of the potential for lower prosthetic wear …

Feasibility of using diamond-like carbon films in total joint replacements: a review

A Roy, A Bennett, L Pruitt - Journal of Materials Science: Materials in …, 2024 - Springer
Diamond-like Carbon (DLC) has been used as a coating material of choice for a variety of
technological applications owing to its favorable bio-tribo-thermo-mechanical …

Metallosis is commonly associated with magnetically controlled growing rods; results from an independent multicentre explant database

PRP Rushton, SL Smith, D Fender, AJ Bowey… - European Spine …, 2021 - Springer
Purpose Determine the incidence of metallosis around MAGEC rods. Methods A multicentre
explant database was searched to identify cases with complete intraoperative findings at rod …

Severe metallosis-related osteolysis as a cause of failure after total knee replacement

KH Salem, N Lindner, M Tingart… - Journal of clinical …, 2020 - Elsevier
Background Metallosis is a syndrome of metal-induced synovitis caused by friction between
two metal surfaces. In contrast to the hip joint after resurfacing arthroplasty or metal-on-metal …