Tresca stress evaluation of Metal-on-UHMWPE total hip arthroplasty during peak loading from normal walking activity

MI Ammarullah, IY Afif, MI Maula, TI Winarni… - Materials Today …, 2022 - Elsevier
Abstract Ultra-High Molecular Weight Polyethylene (UHMWPE) is one of the most widely
used biomaterials for applications in the field of medical devices, especially implants. The …

[PDF][PDF] 2D computational tresca stress prediction of CoCrMo-on-UHMWPE bearing of total hip prosthesis based on body mass index

MI Ammarullah, IY Afif, MI Maula, TI Winarni… - Malays. J. Med …, 2021 - academia.edu
Introduction: Total hip prosthesis has become one of the important aspects of hip joint
replacement surgery. The study about this implant to extent its lifetime is still limited on …

Wear analysis of acetabular cup on metal-on-metal total hip arthroplasty with dimple addition using finite element method

MI Ammarullah, IY Afif, MI Maula, TI Winarni… - AIP Conference …, 2022 - pubs.aip.org
This investigation aims to wear analyze of acetabular cup on metal-on-metal total hip
arthroplasty with and without dimple addition. Our contribution that present in this paper is to …

Deformation analysis of CoCrMo-on-CoCrMo hip implant based on body mass index using 2D finite element procedure

MI Ammarullah, IY Afif, MI Maula… - Journal of Physics …, 2022 - iopscience.iop.org
The paper available of total hip arthroplasty is still concerned with the external factors of
implant user, but the internal factor that is the user's body weight has not deeply understood …

Bowtie Method: Study of Occupational Health and Safety Risks in Cement Production Process

E Putri, M Lestari, N Novrikasari… - Media Kesehatan …, 2021 - journal.unhas.ac.id
The kiln area is an area that has a very complex hazard potential in the cement production
process. This study aimed to assess the risks of occupational safety and health during the …

2D finite element study of contact pressure on CoCrMo-on-CoCrMo total hip arthroplasty during peak loading based on body mass index

MI Ammarullah, IY Afif, MI Maula, TI Winarni… - AIP Conference …, 2022 - pubs.aip.org
The development of total hip arthroplasty involves a lot of user's external factors from
medical implant, but it does not take into account internal factor that is body mass index. This …

Von Mises stress evaluation of CoCrMo-on-CoCrMo bearing in total hip replacement during normal walking using 2D finite element strategy

MI Ammarullah, IY Afif, MI Maula, TI Winarni… - AIP Conference …, 2023 - pubs.aip.org
Humans carry out various activities in everyday life, where the most frequently performed are
normal walking activities. Loading under this human activity has been adopted by several …

ANALISIS KEBUTUHAN PRIMARY AIR PADA KILN BURNER UNTUK MEMPRODUKSI KLINKER

JRH Panjaitan, F Tursida, G Rahmadini… - JITEK (Jurnal Ilmiah …, 2024 - journal.upgris.ac.id
Klinker merupakan bahan utama dalam produksi semen yang diproduksi dengan proses
kalsinasi pada kiln dengan burner sebagai alat pembakar. Pada penelitian ini diteliti …

Von Mises stress analysis of CoCrMo-on-CoCrMo hip prosthesis based on body mass index: 2D FEM estimation

MI Ammarullah, IY Afif, MI Maula… - AIP Conference …, 2023 - pubs.aip.org
Various studies of total hip arthroplasty from many existing researchers have examined
implant user external factors from implant user. Unfortunately, internal factor of implant user …

Contact pressure on CoCrMo-on-CoCrMo bearing of total hip arthroplasty under normal walking condition using 2D finite element approach

MI Ammarullah, IY Afif, MI Mula, TI Winarni… - AIP Conference …, 2023 - pubs.aip.org
Normal walking has become the most commonly performed activity in daily human life. Many