A review of partial volume correction techniques for emission tomography and their applications in neurology, cardiology and oncology

K Erlandsson, I Buvat, PH Pretorius… - Physics in Medicine …, 2012 - iopscience.iop.org
Accurate quantification in PET and SPECT requires correction for a number of physical
factors, such as photon attenuation, Compton scattering and random coincidences (in PET) …

Partial-volume effect in PET tumor imaging

M Soret, SL Bacharach, I Buvat - Journal of nuclear medicine, 2007 - Soc Nuclear Med
PET has the invaluable advantage of being intrinsically quantitative, enabling accurate
measurements of tracer concentrations in vivo. In PET tumor imaging, indices characterizing …

EANM practice guideline/SNMMI procedure standard for dopaminergic imaging in Parkinsonian syndromes 1.0

S Morbelli, G Esposito, J Arbizu, H Barthel… - European journal of …, 2020 - Springer
Purpose This joint practice guideline or procedure standard was developed collaboratively
by the European Association of Nuclear Medicine (EANM) and the Society of Nuclear …

MIRD pamphlet no. 23: quantitative SPECT for patient-specific 3-dimensional dosimetry in internal radionuclide therapy

YK Dewaraja, EC Frey, G Sgouros… - Journal of Nuclear …, 2012 - Soc Nuclear Med
In internal radionuclide therapy, a growing interest in voxel-level estimates of tissue-
absorbed dose has been driven by the desire to report radiobiologic quantities that account …

EANM procedure guidelines for brain neurotransmission SPECT using 123I-labelled dopamine transporter ligands, version 2

J Darcourt, J Booij, K Tatsch, A Varrone… - European journal of …, 2010 - Springer
These guidelines summarize the current views of the European Association of Nuclear
Medicine Neuroimaging Committee (ENC). The aim of the guidelines is to assist nuclear …

Absolute quantification in SPECT

P Ritt, H Vija, J Hornegger, T Kuwert - European journal of nuclear …, 2011 - Springer
Single-photon emission computed tomography (SPECT) allows the three-dimensional
visualization of radioactivity within the human body and is widely used for clinical purposes …

Review and current status of SPECT scatter correction

BF Hutton, I Buvat, FJ Beekman - Physics in Medicine & Biology, 2011 - iopscience.iop.org
Detection of scattered gamma quanta degrades image contrast and quantitative accuracy of
single-photon emission computed tomography (SPECT) imaging. This paper reviews …

A Monte Carlo and physical phantom evaluation of quantitative In-111 SPECT

B He, Y Du, X Song, WP Segars… - Physics in Medicine & …, 2005 - iopscience.iop.org
Accurate estimation of the 3D in vivo activity distribution is important for dose estimation in
targeted radionuclide therapy (TRT). Although SPECT can potentially provide such …

The basal ganglia matching tools package for striatal uptake semi-quantification: description and validation

P Calvini, G Rodriguez, F Inguglia, A Mignone… - European journal of …, 2007 - Springer
Purpose To design a novel algorithm (BasGan) for automatic segmentation of striatal 123 I-
FP-CIT SPECT. Methods The BasGan algorithm is based on a high-definition, three …

Genetically determined measures of striatal D2 signaling predict prefrontal activity during working memory performance

A Bertolino, P Taurisano, NM Pisciotta, G Blasi, L Fazio… - PloS one, 2010 - journals.plos.org
Background Variation of the gene coding for D2 receptors (DRD2) has been associated with
risk for schizophrenia and with working memory deficits. A functional intronic SNP …