Development of a fast proton range radiography system for quality assurance in hadrontherapy

M Bucciantonio, U Amaldi, R Kieffer, F Sauli… - Nuclear Instruments and …, 2013 - Elsevier
We describe the development of a Proton Range Radiography system with an imaging area
of 30× 30 cm 2 for two dimensional mapping of the integrated density in a target. Proton …

X-ray fluorescence imaging system for fast mapping of pigment distributions in cultural heritage paintings

A Zielińska, W Dąbrowski, T Fiutowski… - Journal of …, 2013 - iopscience.iop.org
Conventional X-ray fluorescence imaging technique uses a focused X-ray beam to scan
through the sample and an X-ray detector with high energy resolution but no spatial …

Application of GEM-based detectors in full-field XRF imaging

W Dąbrowski, T Fiutowski, P Frączek… - Journal of …, 2016 - iopscience.iop.org
X-ray fluorescence spectroscopy (XRF) is a commonly used technique for non-destructive
elemental analysis of cultural heritage objects. It can be applied to investigations of …

A compact system for two-dimensional readout of Gas Electron Multiplier detectors

B Mindur, W Dąbrowski, T Fiutowski… - Journal of …, 2013 - iopscience.iop.org
There is a growing interest in the use of Gas Electron Multiplier (GEM) and other micro-
pattern gas detectors (MPGD) for two-dimensional (2-D) position sensitive measurements of …

Investigation of copper-less gas electron multiplier detectors responses to soft x-rays

B Mindur, T Fiutowski, S Koperny, P Wiącek… - Sensors, 2020 - mdpi.com
In this paper, we report on the systematic study of different variants of X-ray detectors based
on Gas Electron Multiplier (GEM) technology using modified GEM foils with greatly reduced …

Performance of a GEM detector with copper-less foils

B Mindur, T Fiutowski, S Koperny… - Journal of …, 2017 - iopscience.iop.org
In this paper we present results of systematic investigation of a GEM detector built of GEM
foils and the drift electrode with mostly removed copper cladding, keeping in mind possible …

Performance of a Micro-Strip Gas Chamber for event wise, high rate thermal neutron detection with accurate 2D position determination

B Mindur, S Alimov, T Fiutowski, C Schulz… - Journal of …, 2014 - iopscience.iop.org
Abstract A two-dimensional (2D) position sensitive detector for neutron scattering
applications based on low-pressure gas amplification and micro-strip technology was built …

A general purpose ethernet based readout data acquisition system

B Mindur, L Jachymczyk - 2011 IEEE Nuclear Science …, 2011 - ieeexplore.ieee.org
A flexible dedicated readout system is one of the most important part of any kind of
dedicated detection system, especially for its testing phase as well as when the final system …

Modelling of vignetting effects in full-field X-ray fluorescence imaging system based on pinhole optics

PM Wróbel, T Fiutowski, S Koperny, M Lankosz… - … Acta Part B: Atomic …, 2020 - Elsevier
The full field X-ray fluorescence (FF-XRF) imaging is a technique capable of analysing the
spatial distribution of elements in a sample. An alternative technique is the scanning macro …

DAQ software for GEM-based imaging system

B Mindur, T Fiutowski, S Koperny… - Journal of …, 2018 - iopscience.iop.org
In the paper we report on the development of a dedicated data acquisition (DAQ) software
being part of a full-filed X-ray fluorescence spectroscopy (XRF) imaging system based on a …