[HTML][HTML] Long-term continuous dynamic monitoring of an eight-story CLT building

A Aloisio, DP Pasca, B Kurent, R Tomasi - Mechanical Systems and Signal …, 2025 - Elsevier
This paper presents the continuous monitoring of an eight-story cross-laminated timber
(CLT) building. The monitoring process includes daily acceleration measurements at the …

Identification of modal properties of a tall glue-laminated timber frame building under long-term ambient vibrations and forced vibrations

S Tulebekova, WK Ao, A Pavic, KA Malo… - Journal of Structural …, 2024 - ascelibrary.org
This paper presents a unique study on the dynamic identification of the tallest glue-
laminated timber frame building in the world using forced vibration tests (FVTs) and long …

Tracking long-term modal behaviour of a footbridge and identifying potential SHM approaches

WK Ao, D Hester, C O'Higgins, J Brownjohn - Journal of Civil Structural …, 2024 - Springer
Numerous studies have investigated the long-term monitoring of natural frequencies,
primarily focusing on medium–large highway bridges, using expensive monitoring systems …

Modelling of Multi-Storey Cross-Laminated Timber Buildings for Vibration Serviceability

B Kurent, N Friedman, B Brank - Buildings, 2024 - mdpi.com
In this study, the vibration serviceability of multi-storey timber buildings is addressed. The
core of this study pertains to the preparation of a comprehensive finite element model to …

FRF-based model updating of liquid-filled pipeline system considering tolerance intervals of test errors in the antiresonant frequencies

H Chen, L Zhang, T Zhang, B Li, X Li - Engineering Structures, 2024 - Elsevier
The frequency response function (FRF)-based model updating technique is an effective
method to calibrate system parameters of the dynamic simulation model of pipeline systems …

Decentralised H robust control of MTMDs for mitigating vibration of a slender MDOF floor configuration

WK Ao, QC Tang, A Pavic - Thin-Walled Structures, 2024 - Elsevier
In this research, a novel robust decentralised H (H∞ and H 2) design combined with a
pattern search method (PSM), incorporating considerations of multiple modal dynamics, was …

Nonlinear finite element model updating and fourier neural operator for digital twin of reinforced concrete containment vessel under seismic excitations

S Fu, CC Chang, C Kaewnuratchadasorn, J Wang… - Engineering …, 2025 - Elsevier
A series of unidirectional seismic excitation tests on a 1/20 scaled reinforced concrete
containment vessel (RCCV) specimen was conducted using a 6-DOF shake table. This …

Vibration-based monitoring of a cross-laminated timber building in a high seismicity zone

A Jara-Cisterna, F Benedetti, V Rosales… - Journal of Civil …, 2024 - Springer
Cross-laminated timber (CLT) buildings have emerged as an alternative to make more
sustainable and resilient cities. However, very few cases of vibration-based monitoring of …

[HTML][HTML] Bayesian model updating of eight-storey CLT building using modal data

B Kurent, N Friedman, A Aloisio, D Pasca… - Probabilistic …, 2024 - Elsevier
The serviceability of tall timber buildings due to wind-induced vibrations is often a governing
design criterion. However, accurate modelling of such buildings for their serviceability is a …

[PDF][PDF] On finite element modelling and model updating of multi-storey timber buildings

B Kurent, B Brank, WK Ao, A Pavic… - World Conference on …, 2023 - researchgate.net
The results of three case studies of timber and hybrid timber buildings have been reviewed.
For each case study, experimentally obtained modal data was available. A detailed …