Real‐time control of shunt active power filter under distorted grid voltage and unbalanced load condition using self‐tuning filter

S Biricik, S Redif, ÖC Özerdem… - IET Power …, 2014 - Wiley Online Library
In this paper, an alternative control method is proposed to improve the harmonic
suppression efficiency of the active power filter in a distorted and an unbalanced power …

A novel strategy for high performance fault tolerant control of shunt active power filter

K Frifita, M Boussak - Electrical Engineering, 2022 - Springer
In this paper, a novel fault tolerant control (FTC) of the SAPF configuration is proposed and
evaluated with balanced and unbalanced loads. The FTC operation is used in order to …

A frequency adaptive control scheme for a three-phase shunt active power filter

SF Al-Gahtani, RM Nelms - Electrical Engineering, 2021 - Springer
The propagation of nonlinear loads and distributed power generation systems can cause
power quality problems such as harmonic distortion, system imbalance, and resonance …

Control of the single phase parallel active filter under weak grid voltages

S Biricik, S Redif, SK Khadem… - 2014 IEEE 5th …, 2014 - ieeexplore.ieee.org
In this study, a control method is proposed to improve the harmonic suppression efficiency of
the single phase active power filter in a distorted power system environment. Here, we …

A novel harmonic identification algorithm for the active power filters in non-ideal voltage source systems

P Santiprapan, K Areerak, K Areerak - Journal of Power Electronics, 2017 - koreascience.kr
This paper describes an intensive analysis of a harmonic identification algorithm in non-
ideal voltages source systems. The dq-axis Fourier with a positive sequence voltage …

Control of the dynamic voltage restorer to improve voltage quality

S Biricik, SK Khadem, S Redif… - 2014 IEEE 5th …, 2014 - ieeexplore.ieee.org
In this study a method is proposed in order to improve the voltage compensation
performance of Dynamic Voltage Restorer by using Self Tuning Filter. The proposed control …

A Robust Three-Phase Shunt Active Power Filter with Frequency Adaptive PR Controller and Sensorless Voltage Control

M Alathamneh, H Ghanayem… - 2023 IEEE Industry …, 2023 - ieeexplore.ieee.org
In this paper, a frequency adaptive control scheme for a three-phase shunt active power filter
is presented. The proposed control system is based on a estimation of the fundamental …

[PDF][PDF] Design of unified power quality conditioner for power quality improvement in distribution network

S Biricik - Balkan Journal of Electrical and Computer Engineering, 2018 - dergipark.org.tr
Unified Power Quality Conditioner (UPQC) is one of the most advanced Custom-Power-
Devices in use today to improve the quality of Power (PQ) in the distribution network. UPQC …

Combined operation system of SVG and APF parallel bus under unbalanced grid

Z Fu, Y Dong - 2018 IEEE 3rd Advanced Information …, 2018 - ieeexplore.ieee.org
Aiming at the problem of excessive volume and system loss of parallel hybrid APF and
reactive power compensation device under unbalanced grid, A kind of SVG and APF and …

[PDF][PDF] Вплив фільтра в каналі керування контуром стабілізації напруги накопичувального конденсатора на динаміку трифазного паралельного активного …

КІ Денисенко, ВО Лесик, ТВ Мисак - … Національної академії наук …, 2021 - prc.ied.org.ua
Анотація Об'єктом дослідження є силовий трифазний паралельний активний фільтр,
який складається з напівпровідникового інвертора напруги на повністю керованих …