Evolution of PET detectors and event positioning algorithms using monolithic scintillation crystals

A Gonzalez-Montoro, AJ Gonzalez… - … on Radiation and …, 2021 - ieeexplore.ieee.org
The use of monolithic scintillator-based photon detectors in positron emission tomography
(PET) has emerged as an attractive alternative to traditional pixelated array designs …

Experimental validation of a rodent PET scanner prototype based on a single LYSO crystal tube

M Freire, A Gonzalez-Montoro… - IEEE transactions on …, 2021 - ieeexplore.ieee.org
Improving sensitivity and spatial resolution in small animal positron emission tomography
imaging instrumentation constitutes one of the main goals of nuclear imaging research …

Novel method to measure the intrinsic spatial resolution in PET detectors based on monolithic crystals

A González-Montoro, F Sanchez, P Bruyndonckx… - Nuclear Instruments and …, 2019 - Elsevier
The main aim of this work is to provide a method to retrieve the intrinsic spatial resolution of
a gamma-ray detector block based on monolithic crystals within an assembled scanner. This …

Calibration of gamma ray impacts in monolithic-based detectors using voronoi diagrams

M Freire, A Gonzalez-Montoro… - … on Radiation and …, 2019 - ieeexplore.ieee.org
Molecular imaging systems, such as positron emission tomography (PET), use detectors
providing energy and a 3-D interaction position of a gamma ray within a scintillation block …

The MINDVIEW project: First results

JM Benlloch, AJ González, R Pani, E Preziosi… - European …, 2018 - cambridge.org
We present the first results of the MINDVIEW project. An innovative imaging system for the
human brain examination, allowing simultaneous acquisition of PET/MRI images, has been …

Gaussian position-weighted center of gravity algorithm for multiplexed readout

H Poladyan, O Bubon, A Teymurazyan… - Physics in Medicine …, 2020 - iopscience.iop.org
Readout signal multiplexing is a commonly used method to reduce the electronics cost in
positron emission tomography (PET) systems, and the calculation of the scintillation …

Scintillation and cherenkov photon counting detectors with analog silicon photomultipliers for TOF-PET

JW Cates, WS Choong, E Brubaker - Physics in Medicine & …, 2024 - iopscience.iop.org
Objective. Standard signal processing approaches for scintillation detectors in positron
emission tomography (PET) derive accurate estimates for 511 keV photon time of interaction …

[HTML][HTML] Reducing calibration time in PET systems based on monolithic crystals

M Freire, G Cañizares, S Echegoyen… - Frontiers in …, 2021 - frontiersin.org
In the past years, the gamma-ray detector designs based on the monolithic crystals have
demonstrated to be excellent candidates for the design of high-performance PET systems …

Gain invariant coordinate reconstruction for SiPM-Based pixelated gamma detectors with multiplexed readout

H Poladyan, O Bubon, A Teymurazyan… - IEEE Transactions …, 2019 - ieeexplore.ieee.org
Currently, the prevailing high-resolution Positron Emission Tomography (PET) detector
architecture consists of pixelated scintillating crystals coupled to a photosensitive layer, such …

Experimental evaluation of reconstruction algorithms for scintillation crystal array based on charge projection readout

R Shi, Y Chen, X Dang, B Zhu, Z Wang, C Yang… - Nuclear Instruments and …, 2019 - Elsevier
Although the technological advances in hardware of gamma camera lead to an obvious
increase of detector performance, the final reconstructed image is still strongly restricted by …