In vitro thrombogenicity testing of biomaterials

S Braune, RA Latour, M Reinthaler… - Advanced …, 2019 - Wiley Online Library
The short‐and long‐term thrombogenicity of implant materials is still unpredictable, which is
a significant challenge for the treatment of cardiovascular diseases. A knowledge‐based …

[HTML][HTML] Polymer coating embolism from intravascular medical devices—a clinical literature review

AM Chopra, M Mehta, J Bismuth, M Shapiro… - Cardiovascular …, 2017 - Elsevier
Over the past three decades, lubricious (hydrophobic and/or hydrophilic) polymer-coated
devices have been increasingly adopted by interventional physicians and vascular …

Histopathological assessment of fatal ipsilateral intraparenchymal hemorrhages after the treatment of supraclinoid aneurysms with the Pipeline Embolization Device …

YC Hu, VR Deshmukh, FC Albuquerque… - Journal of …, 2014 - thejns.org
Object Delayed ipsilateral intraparenchymal hemorrhage has been observed following
aneurysm treatment with the Pipeline Embolization Device (PED). The relationship of this …

Foreign body emboli following cerebrovascular interventions: clinical, radiographic, and histopathologic features

M Shapiro, MD Ollenschleger… - American Journal …, 2015 - Am Soc Neuroradiology
Foreign material emboli following cerebral, cardiac, and peripheral catheterizations have
been reported since the mid-1990s. Catheter coatings have been frequently implicated. The …

Iatrogenic pulmonary lesions

AC Roden, P Camus - Seminars in Diagnostic Pathology, 2018 - Elsevier
Abstract Treatment of patients often includes the administration of medications and
sometimes radiation. While the intent is to treat an underlying condition, in some cases …

Treatment of ruptured intracranial aneurysms using the Woven EndoBridge device: a two-center experience

R Raj, R Rautio, J Pekkola, M Rahi, M Sillanpää… - World Neurosurgery, 2019 - Elsevier
Background The Woven EndoBridge (WEB) device is a new treatment modality developed
for broad-necked unruptured intracranial aneurysms (IAs) but shows potential for the …

Enhancing brain lesions after endovascular treatment of aneurysms

JP Cruz, T Marotta, C O'Kelly… - American Journal …, 2014 - Am Soc Neuroradiology
Complications of endovascular therapy of aneurysms mainly include aneurysm rupture and
thromboembolic events. The widespread use of MR imaging for follow-up of these patients …

Fighting cardiac thromboembolism during transcatheter procedures: an update on the use of cerebral protection devices in cath labs and EP labs

A Preda, C Montalto, M Galasso, A Munafò, I Garofani… - Life, 2023 - mdpi.com
Intraprocedural stroke is a well-documented and feared potential risk of cardiovascular
transcatheter procedures (TPs). Moreover, subclinical neurological events or covert central …

Hydrophilic polymer embolism: an update for physicians

RI Mehta, RI Mehta - The American journal of medicine, 2017 - amjmed.com
Hydrophilic polymers are widely used as surface coatings on vascular medical devices,
including guidewires, introducer and delivery sheaths, and implantable stents and coils, as …

Histological findings and predictors of cerebral debris from transcatheter aortic valve replacement: the ALSTER experience

T Schmidt, O Akdag, P Wohlmuth… - Journal of the …, 2016 - Am Heart Assoc
Background Histopathological analyses of debris captured by a cerebral protection system
during transcatheter aortic valve replacement have been reported, but the origin of the …