Continuous-flow left ventricular assist devices and valvular heart disease: a comprehensive review

PE Noly, FD Pagani, N Noiseux, JM Stulak… - Canadian Journal of …, 2020 - Elsevier
Mechanical circulatory support with implantable durable continuous-flow left ventricular
assist devices (CF-LVADs) represents an established surgical treatment option for patients …

Physiologic outcome of varying speed rotary blood pump support algorithms: a review study

S Bozkurt - Australasian physical & engineering sciences in …, 2016 - Springer
Rotary blood pumps have the potential to become a viable long-term treatment option for the
heart failure patients to bridge to transplantation or destination therapy. However, these …

Aortic insufficiency in patients with sustained left ventricular systolic dysfunction after axial flow assist device implantation

T Imamura, K Kinugawa, T Fujino, T Inaba… - Circulation …, 2014 - jstage.jst.go.jp
Background: Predicting the occurrence of aortic insufficiency (AI) during left ventricular assist
device (LVAD) support has remained unsolved. Methods and Results: We enrolled 52 …

The influence of rotary blood pump speed modulation on the risk of intraventricular thrombosis

S Liao, EL Wu, M Neidlin, Z Li, B Simpson… - Artificial …, 2018 - Wiley Online Library
Rotary left ventricular assist devices (LVADs) are commonly operated at a constant speed,
attenuating blood flow pulsatility. Speed modulation of rotary LVADs has been demonstrated …

Mock circulatory test rigs for the in vitro testing of artificial cardiovascular organs

Y Shi, H Yang - Journal of Medical Engineering & Technology, 2019 - Taylor & Francis
In vitro study plays an important role in the experimental study of cardiovascular dynamics.
An essential hardware facility that mimics the blood flow changes and provides the required …

Valvular regurgitation in a biventricular mock circulatory loop

S Shehab, SM Allida, PJ Newton, D Robson… - Asaio …, 2019 - journals.lww.com
Aortic regurgitation (AR), mitral regurgitation (MR), and tricuspid regurgitation (TR) after
continuous-flow left ventricular assist device (LVAD) are common and may increase with …

Pulsatile vs. continuous flow

EL Wu, M Kleinheyer, A Ündar - Mechanical circulatory and respiratory …, 2018 - Elsevier
Earlier left ventricular assist devices (LVADs) were volume displacement pumps (VDPs) that
delivered pulsatile flow. However, due to improved survival rates of rotary blood pumps …

Pulsatile versus continuous flow

S Heinsar, EL Wu, S Ajamu, A Ündar - Mechanical Circulatory and …, 2025 - Elsevier
Left ventricular assist device (LVAD) developments were initially volume displacement
pumps (VDPs) that delivered pulsatile flow. However, due to their reduced survival rates …

The hemodynamic effects of the LVAD outflow cannula location on the thrombi distribution in the aorta: A primary numerical study

Y Zhang, B Gao, C Yu - Computer Methods and Programs in Biomedicine, 2016 - Elsevier
Although a growing number of patients undergo LVAD implantation for heart failure
treatment, thrombi are still the devastating complication for patients who used LVAD. LVAD …

Hemodynamic effects of support modes of LVADs on the aortic valve

B Gao, Q Zhang, Y Chang - Medical & Biological Engineering & Computing, 2019 - Springer
As the alternative treatment for heart failure, left ventricular assist devices (LVADs) have
been widely applied to clinical practice. However, the effects of the support modes of LVADs …