Towards automated statistical partial discharge source classification using pattern recognition techniques

H Janani, B Kordi - High Voltage, 2018 - Wiley Online Library
This study presents a comprehensive review of the automated classification in partial
discharge (PD) source identification and probabilistic interpretation of the classification …

Wind generators ferroresonance overvoltage protection methods: A review

M Hesami, M Bigdeli, MA Fatemi… - 2023 8th International …, 2023 - ieeexplore.ieee.org
Ferroresonance, as a sustained transient phenomenon associated with excessive voltages
and currents, can cause severe consequences if not mitigated properly. In that regard …

Voltage transformer ferroresonance: An inhibitor device

A Heidary, K Rouzbehi… - IEEE Transactions on …, 2020 - ieeexplore.ieee.org
Ferroresonance occurrence is a source of damage, causing overvoltage on voltage
transformer (VT) and isolators of the grid equipment. Some solutions are available to protect …

A multifunction high-temperature superconductive power flow controller and fault current limiter

A Heidary, H Radmanesh, K Rouzbehi… - IEEE Transactions …, 2020 - ieeexplore.ieee.org
This article presents a novel high-temperature superconductive (HTS) power flow controller
and current limiter (PFCCL), which limits fault currents and manages power flow in the …

[HTML][HTML] Analytical solution of serial ferroresonance triggered by circuit breaker operation in solidly grounded power grids

B Wang, C Zhang, Y Xia, F Zhang - … Journal of Electrical Power & Energy …, 2023 - Elsevier
Ferroresonance can be induced by Circuit Breaker (CB) switching operations in neutral
point solidly grounded power grids with matching parameters. No complete time domain …

High ohmic reactor as a shunt limiter (HOR-SL) method for ferroresonance elimination in the distribution system

AM Abdel-Hamed, MM El-Shafhy, EA Badran - IEEE Access, 2022 - ieeexplore.ieee.org
Aberrant system oscillations cause electrical network components to malfunction in a
catastrophic way. Additionally, this results in saturation of the ferromagnetic core …

Dynamic analysis and suppression strategy research on a novel fractional-order ferroresonance system

J Yang, Y Fan, A Mu, J Xiong - Fractal and Fractional, 2023 - mdpi.com
Ferroresonance is characterized by overvoltage and irregular operation in power systems,
which can greatly endanger system equipment. Mechanism analysis of the ferroresonance …

Innovative Solid-State Ferroresonance-Suppressing Circuit for Voltage Transformer Protection in Wind Generation Systems

A Bakhshi, M Bigdeli, M Moradlou, B Behdani… - Energies, 2023 - mdpi.com
Ferroresonance, as an undesirable disturbance, leads to significant overvoltage and
distorted waveforms. This phenomenon can be highly damaging to voltage transformers and …

Microgrids interconnection to upstream AC grid using a dual‐function fault current limiter and power flow controller: principle and test results

N Shafaghatian, A Heidary… - IET Energy Systems …, 2019 - Wiley Online Library
This study presents a novel magnetic‐based solid‐state dual‐function fault current limiter
and power flow controller (FLPFC) that offers a promising application for safe and …

Diagnosis of chaotic ferroresonance phenomena using deep learning

HS Nogay, TC Akinci, MI Akbas, A Tokić - IEEE Access, 2023 - ieeexplore.ieee.org
Ferroresonance is a non-linear and dangerous resonance phenomenon that can affect
power networks and damage electrical equipment. The ferroresonance phenomenon is …