Automatic liquid handling for life science: a critical review of the current state of the art

F Kong, L Yuan, YF Zheng… - Journal of laboratory …, 2012 - journals.sagepub.com
Liquid handling plays a pivotal role in life science laboratories. In experiments such as gene
sequencing, protein crystallization, antibody testing, and drug screening, liquid biosamples …

Measurement uncertainty: Literature review and research trends

P da Silva Hack, CS ten Caten - ieee Transactions on …, 2012 - ieeexplore.ieee.org
This paper reviews and analyzes studies concerning measurement uncertainty, examining
114 papers published between 2004 and 2010 in the following international journals: IEEE …

OpenLH: open liquid-handling system for creative experimentation with biology

G Gome, J Waksberg, A Grishko, IY Wald… - Proceedings of the …, 2019 - dl.acm.org
The biological prototyping revolution is in motion, and new tools are needed to empower
HCI researchers, designers, makers, and bio-enthusiasts to experiment with live organisms …

High-precision digital droplet pipetting enabled by a plug-and-play microfluidic pipetting chip

Y Mao, Y Pan, X Li, B Li, J Chu, T Pan - Lab on a Chip, 2018 - pubs.rsc.org
Emerging demands for handling minute liquid samples and reagents have been constantly
growing in a wide variety of medical and biological areas. This calls for low-volume and high …

An investigation of natural convection heat transfer from a horizontal cooled finned tube

M Yaghoubi, M Mahdavi - Experimental Heat Transfer, 2013 - Taylor & Francis
Natural convection and radiation heat transfer from annular mounted fins on a horizontal
cylinder is studied experimentally and numerically. For experiments, surrounding air …

Novel gravimetric measurement technique for quantitative volume calibration in the sub-microliter range

D Liang, C Steinert, S Bammesberger… - Measurement …, 2012 - iopscience.iop.org
We present a novel measurement method based on the gravimetric principles adapted from
the ASTM E542 and ISO 4787 standards for quantitative volume determination in the sub …

Validation and estimation of uncertainty for a glucose determination method GOD-PAP using a multi-calibrator as reference

A Rascón-Careaga, MAG Corella-Madueño… - MAPAN, 2021 - Springer
When measuring glucose concentration, assuring the reliability of the results is critical,
because the clinical diagnosis of pathologies related to diabetes mellitus, as well as their …

Quantitative characterization of non-contact microdispensing technologies for the sub-microliter range

S Bammesberger, A Ernst, N Losleben, L Tanguy… - Drug discovery today, 2013 - Elsevier
This work describes how to effectively compare non-contact dispensing technologies for
automated liquid handling under high-throughput screening (HTS) conditions in the range of …

Validation of the ASTM E1898-21 Method with Estimation of Analytical Uncertainty for the Determination of Silver by FAAS

R Martínez-Peñuñuri, P Vázquez-Bustamante… - MAPAN, 2023 - Springer
Silver is one of the most important precious metals in mining and metallurgy. Thus, the
methods used to determine its concentration are critical. The objective of this research work …

[PDF][PDF] 超微量液体容积双波长参比测量方法研究

王金涛, 陈超云, 李志昊, 佟林, 刘子勇, 张珑, 罗志东 - 计量学报, 2015 - jlxb.china-csm.org
为克服静力称重法受蒸发量影响大的不足, 同时适应在线测量的需要, 基于Lambert Beer 定律,
研究了520nm 和730nm 双波长超微液体容量光度吸收测量法, 通过稀溶液浓度与吸光度之间的 …