AC microgrid protection schemes: A comprehensive review

WM Hamanah, MI Hossain, M Shafiullah… - IEEE Access, 2023 - ieeexplore.ieee.org
The power grid infrastructure has evolved from a centralized to a distributed model utilizing
renewable energy sources in the last few years. This trend is likely to continue, given the …

Fault current limiters in power systems: A comprehensive review

MS Alam, MAY Abido, I El-Amin - Energies, 2018 - mdpi.com
Power systems are becoming more and more complex in nature due to the integration of
several power electronic devices. Protection of such systems and augmentation of reliability …

[HTML][HTML] A review of superconducting fault current limiters compared with other proven technologies

GG Sotelo, G dos Santos, F Sass, BW França… - Superconductivity, 2022 - Elsevier
Several substations in operation were commissioned decades ago. These substations are
overstressed, then their protection equipment cannot provide an effective safety condition to …

Review on active distribution networks with fault current limiters and renewable energy resources

AAA El-Ela, RA El-Sehiemy, AM Shaheen, AR Ellien - Energies, 2022 - mdpi.com
To cope with the increasing energy demand, power systems, especially distribution
networks, face many challenges. Recently, these networks have become complex and large …

Inductive fault current limiters: A review

A Heidary, H Radmanesh, K Rouzbehi… - Electric Power Systems …, 2020 - Elsevier
A fault current limiter (FCL) is an effective means of limiting fault currents that is a promising
power system protection solution. This paper presents a comparative survey of research …

Ferroresonance overvoltage mitigation using STATCOM for grid-connected wind energy conversion systems

MI Mosaad, NA Sabiha - Journal of Modern Power Systems and …, 2021 - ieeexplore.ieee.org
We present the ferroresonance overvoltage mitigation concerning the power systems of the
grid-connected wind energy conversion systems (WECSs). WECS is considered based on a …

High ohmic reactor as a shunt limiter (HOR-SL) method for ferroresonance elimination in the distribution system

AM Abdel-Hamed, MM El-Shafhy, EA Badran - IEEE Access, 2022 - ieeexplore.ieee.org
Aberrant system oscillations cause electrical network components to malfunction in a
catastrophic way. Additionally, this results in saturation of the ferromagnetic core …

Research on the mechanism and restraining measures of ferroresonance in distribution network based on ATP-EMTP

H Liu, Q Li, Y Sui, L Liu, H Liu - Electric Power Systems Research, 2023 - Elsevier
In order to monitor the three-phase voltage of the busbar to ground, the substation bus is
usually connected to the electromagnetic voltage transformer by YN connection in the …

Recent trends and developments in protection systems for microgrids incorporating distributed generation

S Ashraf, O Hasan, I Evkay… - Wiley …, 2024 - Wiley Online Library
Microgrids are integral to power grids; they enhance grid reliability by integrating distributed
generators (DGs) to fulfill the local load requirements, lowering energy generation costs, and …

Design consideration of a dual-functional bridge-type fault current limiter

F Jiang, S Cheng, C Tu, Q Guo, R Zhu… - IEEE journal of …, 2019 - ieeexplore.ieee.org
To sufficiently utilize a bridge-type fault current limiter (BTFCL) in the distribution grids, this
article proposes a dual-functional BTFCL (DF-BTFCL), which can work either at the BTFCL …