Dose calculation for photon‐emitting brachytherapy sources with average energy higher than 50 keV: report of the AAPM and ESTRO

J Perez‐Calatayud, F Ballester, RK Das… - Medical …, 2012 - Wiley Online Library
Purpose: Recommendations of the American Association of Physicists in Medicine (AAPM)
and the European Society for Radiotherapy and Oncology (ESTRO) on dose calculations for …

[图书][B] The physics of modern brachytherapy for oncology

D Baltas, L Sakelliou, N Zamboglou - 2006 - taylorfrancis.com
Brachytherapy has become the modality of choice for several cancer localizations,
minimizing the possibility of unacceptable risks for healthy tissues and providing a more cost …

EGSnrc Monte Carlo calculated dosimetry parameters for and brachytherapy sources

REP Taylor, DWO Rogers - Medical physics, 2008 - Wiley Online Library
This study presents the results of EGSnrc Monte Carlo calculations of the dose distribution
surrounding a high dose rate brachytherapy source and 14 high dose rate and pulsed dose …

Quantifying tumor-selective radiation dose enhancements using gold nanoparticles: a monte carlo simulation study

SX Zhang, J Gao, TA Buchholz, Z Wang… - Biomedical …, 2009 - Springer
Gold nanoparticles can enhance the biological effective dose of radiation delivered to
tumors, but few data exist to quantify this effect. The purpose of this project was to build a …

Characterization of a fiber‐coupled luminescence dosimetry system for online in vivo dose verification during brachytherapy

CE Andersen, SK Nielsen, S Greilich… - Medical …, 2009 - Wiley Online Library
A prototype of a new dose‐verification system has been developed to facilitate prevention
and identification of dose delivery errors in remotely afterloaded brachytherapy. The system …

Brachytherapy source characterization for improved dose calculations using primary and scatter dose separation

KR Russell, ÅK Carlsson Tedgren… - Medical physics, 2005 - Wiley Online Library
In brachytherapy, tissue heterogeneities, source shielding, and finite patient/phantom
extensions affect both the primary and scatter dose distributions. The primary dose is, due to …

Time‐resolved in vivo luminescence dosimetry for online error detection in pulsed dose‐rate brachytherapy

CE Andersen, SK Nielsen, JC Lindegaard… - Medical …, 2009 - Wiley Online Library
Purpose: The purpose of this study is to present and evaluate a dose‐verification protocol for
pulsed dose‐rate (PDR) brachytherapy based on in vivo time‐resolved (1 s time resolution) …

Update of the CLRP Monte Carlo TG‐43 parameter database for high‐energy brachytherapy sources

H Safigholi, MJP Chamberland, REP Taylor… - Medical …, 2023 - Wiley Online Library
Purpose To update and extend version 2 of the Carleton Laboratory for Radiotherapy
Physics (CLRP) TG‐43 dosimetry database (CLRP_TG43v2) for high‐energy (HE,≥ 50 …

A dosimetric study on the high dose rate Flexisource

D Granero, J Pérez‐Calatayud, E Casal… - Medical …, 2006 - Wiley Online Library
In this work, the dose rate distribution of a new high dose rate source (Flexisource used in
the afterloading Flexitron system, Isodose Control, Veenendaal, The Netherlands) is studied …

Dosimetric accuracy of a deterministic radiation transport based brachytherapy treatment planning system. Part I: Single sources and bounded homogeneous …

K Zourari, E Pantelis, A Moutsatsos… - Medical …, 2010 - Wiley Online Library
Purpose: The aim of this work is to validate a deterministic radiation transport based
treatment planning system (TPS) for single brachytherapy source dosimetry in …