[HTML][HTML] Biomechanical analysis of plate systems for proximal humerus fractures: a systematic literature review

A Jabran, C Peach, L Ren - Biomedical engineering online, 2018 - Springer
Background Proximal humerus fractures are the third most common in the human body but
their management remains controversial. Open reduction and internal fixation with plates is …

Supraspinatus tendon load during abduction is dependent on the size of the critical shoulder angle: a biomechanical analysis

C Gerber, JG Snedeker, D Baumgartner… - Journal of …, 2014 - Wiley Online Library
Shoulders with supraspinatus (SSP) tears are associated with significantly larger critical
shoulder angles (CSA) compared to disease‐free shoulders. We hypothesized that larger …

Implant design variations in reverse total shoulder arthroplasty influence the required deltoid force and resultant joint load

JW Giles, DGG Langohr, JA Johnson… - … and Related Research …, 2015 - journals.lww.com
Background Reverse total shoulder arthroplasty (RTSA) is widely used; however, the effects
of RTSA geometric parameters on joint and muscle loading, which strongly influence implant …

Effect of lateral offset center of rotation in reverse total shoulder arthroplasty: a biomechanical study

HB Henninger, A Barg, AE Anderson… - Journal of shoulder and …, 2012 - Elsevier
BACKGROUND: Lateral offset center of rotation (COR) reduces the incidence of scapular
notching and potentially increases external rotation range of motion (ROM) after reverse …

Moment arms of the muscles crossing the anatomical shoulder

DC Ackland, P Pak, M Richardson… - Journal of …, 2008 - Wiley Online Library
The objective of the present study was to determine the instantaneous moment arms of 18
major muscle sub‐regions crossing the glenohumeral joint during coronal‐plane abduction …

Does the dynamic sling effect of the Latarjet procedure improve shoulder stability? A biomechanical evaluation

JW Giles, HW Boons, I Elkinson, KJ Faber… - Journal of shoulder and …, 2013 - Elsevier
INTRODUCTION: Glenohumeral instability with glenoid bone loss is commonly treated with
the Latarjet procedure. The procedure involves transfer of the coracoid and conjoint tendon …

Effect of deltoid tension and humeral version in reverse total shoulder arthroplasty: a biomechanical study

HB Henninger, A Barg, AE Anderson… - Journal of shoulder and …, 2012 - Elsevier
BACKGROUND: No clear recommendations exist regarding optimal humeral component
version and deltoid tension in reverse total shoulder arthroplasty (TSA). MATERIALS AND …

The effect of the remplissage procedure on shoulder stability and range of motion: an in vitro biomechanical assessment

I Elkinson, JW Giles, KJ Faber, HW Boons, LM Ferreira… - JBJS, 2012 - journals.lww.com
Background: The remplissage procedure may be performed as an adjunct to Bankart repair
to treat recurrent glenohumeral dislocation associated with an engaging Hill-Sachs humeral …

Moderate to large engaging Hill-Sachs defects: an in vitro biomechanical comparison of the remplissage procedure, allograft humeral head reconstruction, and partial …

JW Giles, I Elkinson, LM Ferreira, KJ Faber… - Journal of shoulder and …, 2012 - Elsevier
BACKGROUND: The management of engaging Hill-Sachs defects (HSD) is controversial.
The purpose of this study was to biomechanically compare 3 treatment strategies …

Glenohumeral joint reaction forces increase with critical shoulder angles representative of osteoarthritis—a biomechanical analysis

AF Viehöfer, JG Snedeker… - Journal of …, 2016 - Wiley Online Library
Osteoarthritis (OA) of the glenohumeral joint constitutes the most frequent indication for
nontraumatic shoulder joint replacement. Recently, a small critical shoulder angle (CSA) …