Review of international grid codes for wind power integration: Diversity, technology and a case for global standard

M Mohseni, SM Islam - Renewable and Sustainable Energy Reviews, 2012 - Elsevier
This paper presents a comprehensive study on the latest grid code regulations enforced by
transmission system operators on large wind power plants (WPPs). First, the most common …

Faults and Fault Ride Through strategies for grid-connected photovoltaic system: A comprehensive review

K Zeb, SU Islam, I Khan, W Uddin, M Ishfaq… - … and Sustainable Energy …, 2022 - Elsevier
With the exponential penetration of Photovoltaic (PV) plants into the power grid, protection
has gained exceptional importance in recent years for ensuring stability, reliability, security …

Advanced control strategy of DFIG wind turbines for power system fault ride through

L Yang, Z Xu, J Ostergaard, ZY Dong… - IEEE Transactions on …, 2011 - ieeexplore.ieee.org
This paper presents an advanced control strategy for the rotor and grid side converters of the
doubly fed induction generator (DFIG) based wind turbine (WT) to enhance the low-voltage …

Rotor voltage dynamics in the doubly fed induction generator during grid faults

FKA Lima, A Luna, P Rodriguez… - … on power electronics, 2009 - ieeexplore.ieee.org
This paper presents a new control strategy for the rotor-side converter (RSC) of wind
turbines (WTs) based on doubly fed induction generators (DFIG) that intends to improve its …

Multiterminal DC wind farm collection grid internal fault analysis and protection design

J Yang, JE Fletcher, J O'Reilly - IEEE transactions on power …, 2010 - ieeexplore.ieee.org
The multiterminal dc wind farm is a promising topology with a voltage-source inverter (VSI)
connection at the onshore grid. Voltage-source converters (VSCs) are robust to ac-side fault …

An LVRT control strategy based on flux linkage tracking for DFIG-based WECS

S Xiao, G Yang, H Zhou, H Geng - IEEE Transactions on …, 2012 - ieeexplore.ieee.org
For doubly fed induction generator (DFIG)-based wind energy conversion systems (WECSs),
large electromotive force will be induced in the rotor circuit during grid faults. Without proper …

A series-dynamic-resistor-based converter protection scheme for doubly-fed induction generator during various fault conditions

J Yang, JE Fletcher, J O'Reilly - IEEE Transactions on Energy …, 2010 - ieeexplore.ieee.org
This paper proposes a new converter protection method, primarily based on a series
dynamic resistor (SDR) that avoids the doubly-fed induction generator (DFIG) control being …

Wind farms fault ride through using DFIG with new protection scheme

KE Okedu, SM Muyeen, R Takahashi… - IEEE transactions on …, 2012 - ieeexplore.ieee.org
This paper proposes a control strategy of doubly fed induction generators (DFIGs) with new
protection schemes for enhancing fault ride through capability of wind farms composed of …

Reactive power capability of wind turbines based on doubly fed induction generators

S Engelhardt, I Erlich, C Feltes… - IEEE Transactions …, 2010 - ieeexplore.ieee.org
With the increasing penetration of wind turbines (WTs) grid utilities require extended reactive
power supply capability not only during voltage dips but also in steady-state operation. WTs …

Enhanced fault ride-through method for wind farms connected to the grid through VSC-based HVDC transmission

C Feltes, H Wrede, FW Koch… - IEEE Transactions on …, 2009 - ieeexplore.ieee.org
This paper describes a new control approach for secure fault-ride through of wind farms
connected to the grid through a voltage source converter-based high voltage DC …