Dose calculations for external photon beams in radiotherapy

A Ahnesjö, MM Aspradakis - Physics in Medicine & Biology, 1999 - iopscience.iop.org
Dose calculation methods for photon beams are reviewed in the context of radiation therapy
treatment planning. Following introductory summaries on photon beam characteristics and …

History of tomotherapy

TR Mackie - Physics in Medicine & Biology, 2006 - iopscience.iop.org
Tomotherapy is the delivery of intensity modulated radiation therapy using rotational delivery
of a fan beam in the manner of a CT scanner. In helical tomotherapy the couch and gantry …

Dosimetric validation of Acuros® XB with Monte Carlo methods for photon dose calculations

K Bush, IM Gagne, S Zavgorodni, W Ansbacher… - Medical …, 2011 - Wiley Online Library
Purpose: The dosimetric accuracy of the recently released Acuros® XB advanced dose
calculation algorithm (Varian Medical Systems, Palo Alto, CA) is investigated for single …

Comparison of dose calculation algorithms for treatment planning in external photon beam therapy for clinical situations

T Knöös, E Wieslander, L Cozzi, C Brink… - Physics in Medicine …, 2006 - iopscience.iop.org
A study of the performance of five commercial radiotherapy treatment planning systems
(TPSs) for common treatment sites regarding their ability to model heterogeneities and …

Optimizing the delivery of radiation therapy to cancer patients

DM Shepard, MC Ferris, GH Olivera, TR Mackie - Siam Review, 1999 - SIAM
In the field of radiation therapy, much of the research is aimed at developing new and
innovative techniques for treating cancer patients with radiation. In recent years, new …

Dose calculation algorithms for external radiation therapy: an overview for practitioners

F De Martino, S Clemente, C Graeff, G Palma, L Cella - Applied sciences, 2021 - mdpi.com
Featured Application Radiation therapy treatment planning. Abstract Radiation therapy (RT)
is a constantly evolving therapeutic technique; improvements are continuously being …

On the dosimetric behaviour of photon dose calculation algorithms in the presence of simple geometric heterogeneities: comparison with Monte Carlo calculations

A Fogliata, E Vanetti, D Albers, C Brink… - Physics in Medicine …, 2007 - iopscience.iop.org
A comparative study was performed to reveal differences and relative figures of merit of
seven different calculation algorithms for photon beams when applied to inhomogeneous …

Algorithms and functionality of an intensity modulated radiotherapy optimization system

Q Wu, R Mohan - Medical physics, 2000 - Wiley Online Library
The main purpose of this paper is to describe formalisms, algorithms, and certain unique
features of a system for optimization of intensity modulated radiotherapy (IMRT). The system …

Accuracy of patient dose calculation for lung IMRT: A comparison of Monte Carlo, convolution/superposition, and pencil beam computations

B Vanderstraeten, N Reynaert, L Paelinck… - Medical …, 2006 - Wiley Online Library
The accuracy of dose computation within the lungs depends strongly on the performance of
the calculation algorithm in regions of electronic disequilibrium that arise near tissue …

Dosimetric evaluation of heterogeneity corrections for RTOG 0236: Stereotactic body radiotherapy of inoperable stage I-II non–small-cell lung cancer

Y Xiao, L Papiez, R Paulus, R Timmerman… - International Journal of …, 2009 - Elsevier
PURPOSE: Using a retrospective analysis of treatment plans submitted from multiple
institutions accruing patients to the Radiation Therapy Oncology Group (RTOG) 0236 non …