The deconvolution problem: An overview

SM Riad - Proceedings of the IEEE, 1986 - ieeexplore.ieee.org
This paper is a tutorial review of the deconvolution problem. It reviews the definitions of
convolution and deconvolution and discusses both the time-domain and frequency-domain …

A new algorithm for wire fault location using time-domain reflectometry

Q Shi, O Kanoun - IEEE Sensors Journal, 2013 - ieeexplore.ieee.org
In time domain reflectometry (TDR) attenuation and dispersion of the reflected signal limit
the reachable accuracy for wire faults location. Because time of flight is evaluated, the wire …

50 years of RF and microwave sampling

M Kahrs - IEEE Transactions on Microwave Theory and …, 2003 - ieeexplore.ieee.org
Measurement of microwave and UHF signals is often done with sampling techniques. In this
paper, the techniques and technology of sampling of electrical signals is reviewed from …

An optimization technique for iterative frequency-domain deconvolution

A Bennia, SM Riad - IEEE transactions on instrumentation and …, 1990 - ieeexplore.ieee.org
A technique for the optimization of the iteration (design) parameter of filters used in
frequency-domain iterative deconvolution methods is presented. The technique allows the …

Dynamic calibration of waveform recorders and oscilloscopes using pulse standards

WL Gans - IEEE transactions on instrumentation and …, 1990 - ieeexplore.ieee.org
The current methods used to calibrate oscilloscopes are briefly discussed, and the problems
associated with oscilloscope vertical channel bandwidth testing are illustrated. A method is …

UWB channel impulse response characterization using deconvolution techniques

A Muqaibel, A Safaai-Jazi, B Woerner… - The 2002 45th Midwest …, 2002 - ieeexplore.ieee.org
UWB Channels can be measured by sounding the channel with pulses, and thereby obtain
the impulse response. Multipath components have different waveforms depending on the …

Dual wavelength laser diode excitation source for 2D photoacoustic imaging

TJ Allen, PC Beard - … : Imaging and Sensing 2007: The Eighth …, 2007 - spiedigitallibrary.org
Photoacoustic methods can be used to make spatially resolved spectroscopic
measurements of blood oxygenation when using a multiwavelength excitation source, such …

Multiparameter optimization of inverse filtering algorithms

T Daboczi, I Kollar - IEEE Transactions on Instrumentation and …, 1996 - ieeexplore.ieee.org
This paper investigates inverse filtering of transient signals. The problem is ill-conditioned,
which means that a small uncertainty in the measurement causes large deviations in the …

Study and performance evaluation of two iterative frequency-domain deconvolution techniques

B Parruck, SM Riad - IEEE transactions on instrumentation and …, 1984 - ieeexplore.ieee.org
The performance of two iterative frequency-domain deconvolution techniques, the optimum
compensation and the Guillaume-Nahman, is evaluated. The study involved the …

[PDF][PDF] 空间电荷测量信号恢复中的频域反卷积技术及实现

蔡川, 李旭光, 尹毅, 王雅群 - 电工技术学报, 2009 - dgjsxb.ces-transaction.com
摘要电声脉冲法空间电荷测量系统的输出信号通常存在比较明显的过冲. 本文分析了电声脉冲法
空间电荷测量系统硬件结构造成信号畸变的原因, 介绍了空间电荷测量信号恢复中反卷积处理 …