Toric intraocular lenses: historical overview, patient selection, IOL calculation, surgical techniques, clinical outcomes, and complications

N Visser, NJC Bauer, RMMA Nuijts - Journal of Cataract & Refractive …, 2013 - Elsevier
We present an overview of currently available toric intraocular lenses (IOLs) and multifocal
toric IOLs. Relevant patient selection criteria, IOL calculation issues, and surgical techniques …

[HTML][HTML] Premium intraocular lenses: the past, present and future

J Zvorničanin, E Zvorničanin - Journal of Current Ophthalmology, 2018 - Elsevier
Purpose To present potential benefits as well as limitations of premium intraocular lens (IOL)
use, and provide insight in future of premium cataract surgery. Methods Bibliographic …

New horizons on advanced nanoscale materials for Cultural Heritage conservation

R Mastrangelo, D Chelazzi, P Baglioni - Nanoscale Horizons, 2024 - pubs.rsc.org
Nanomaterials have permeated numerous scientific and technological fields, and have
gained growing importance over the past decades also in the preservation of Cultural …

Image-guided system versus manual marking for toric intraocular lens alignment in cataract surgery

VSC Webers, NJC Bauer, N Visser… - Journal of Cataract & …, 2017 - Elsevier
Purpose To compare the accuracy of toric intraocular lens (IOL) alignment using the Verion
Image-Guided System versus a conventional manual ink-marking procedure. Setting …

Cataract surgery with toric intraocular lens implantation in patients with high corneal astigmatism

N Visser, R Ruíz-Mesa, F Pastor, NJC Bauer… - Journal of Cataract & …, 2011 - Elsevier
PURPOSE: To evaluate the visual and refractive outcomes after toric intraocular lens (IOL)
implantation in patients with high amounts of corneal astigmatism. SETTING: University Eye …

Comparison of posterior capsule opacification with hydrophobic acrylic and hydrophilic acrylic intraocular lenses

AR Vasavada, SM Raj, A Shah, G Shah… - Journal of Cataract & …, 2011 - Elsevier
Purpose To compare posterior capsule opacification (PCO) 3 years postoperatively in
contralateral eyes with a single-piece hydrophobic acrylic and 1 of 2 single-piece …

Biomechanics of the anterior human corneal tissue investigated with atomic force microscopy

M Lombardo, G Lombardo, G Carbone… - … & visual science, 2012 - iovs.arvojournals.org
Purpose.: To investigate the biomechanics of the anterior human corneal stroma using
atomic force microscopy (AFM). Methods.: AFM measurements were performed in liquid on …

Hydrophobic versus double-square-edged hydrophilic foldable acrylic intraocular lens: effect on posterior capsule opacification

T Iwase, Y Nishi, BC Oveson, YJ Jo - Journal of Cataract & Refractive …, 2011 - Elsevier
Purpose To evaluate posterior capsule opacification (PCO) 2 years after cataract surgery
with implantation of a hydrophobic acrylic or single-piece sharp-edged hydrophilic acrylic …

Surgical management of astigmatism with toric intraocular lenses

BV Ventura, L Wang, MP Weikert… - Arquivos Brasileiros …, 2014 - SciELO Brasil
Correction of corneal astigmatism is a key element of cataract surgery, since post-surgical
residual astigmatism can compromise the patient's uncorrected visual acuity. Toric …

Impact of Material and Lens Design on Repositioning Surgery of Toric Intraocular Lenses: A Single‐Arm Meta‐Analysis

J Wu, C Yang, Y Yin, L Liu, H Wang - Journal of Ophthalmology, 2022 - Wiley Online Library
Aim. To analyze the pooled incidence rate in repositioning surgery by considering different
materials and designs. Methods. All published studies investigating the repositioning …