Adverse environmental effects of disposable face masks due to the excess usage

ASH Li, P Sathishkumar, ML Selahuddeen… - Environmental …, 2022 - Elsevier
The widespread use of disposable face masks as a preventative strategy to address
transmission of the SARS-CoV-2 virus has been a key environmental concern since the …

Selected analytical challenges in the determination of pharmaceuticals in drinking/marine waters and soil/sediment samples

A Białk-Bielińska, J Kumirska, M Borecka… - … of Pharmaceutical and …, 2016 - Elsevier
Recent developments and improvements in advanced instruments and analytical
methodologies have made the detection of pharmaceuticals at low concentration levels in …

A new approach for the estimation of expanded uncertainty of results of an analytical method developed for determining antibiotics in seawater using solid-phase …

M Borecka, A Białk-Bielińska, G Siedlewicz… - … of Chromatography A, 2013 - Elsevier
Although the uncertainty estimate should be a necessary component of an analytical result,
the presentation of measurements together with their uncertainties is still a serious problem …

Residues and chiral signatures of organochlorine pesticides in mollusks from the coastal regions of the Yangtze River Delta: Source and health risk implication

S Zhou, Q Tang, M Jin, W Liu, L Niu, H Ye - Chemosphere, 2014 - Elsevier
The residues and enantiomeric fractions of organochlorine pesticides (OCPs) were
measured in 11 mollusk species collected from the coastal areas along the Yangtze River …

Evaluation of benzene residue in edible oils using Fourier transform infrared (FTIR) spectroscopy

R Joshi, BK Cho, S Lohumi, R Joshi, J Lee… - Korean Journal of …, 2019 - dbpia.co.kr
The use of food grade hexane (FGH) for edible oil extraction is responsible for the presence
of benzene in the crude oil. Benzene is a Group 1 carcinogen and could pose a serious …

Estimating precision and accuracy of GC-TCD method for carbon dioxide, propane and carbon monoxide determination at different flow rate of carrier gas

O Zuas, H Budiman - Hemijska industrija, 2016 - doiserbia.nb.rs
Investigation on precision and accuracy of gas chromatography equipped with thermal
conductivity detector (GC-TCD) method for the measurement of CO2, C3H8, and CO as …

[PDF][PDF] Trace measurement of CO, CH4, and CO2 in high purity gases by GC-FID-methanizer: method validation and uncertainty estimation

H Budiman, O Zuas - Scientific Study & Research, 2017 - pubs.ub.ro
In this study, method validation and uncertainty estimation for the measurement of trace
amounts gas impurities such as carbon monoxide (CO), methane (CH4), and carbon dioxide …

Estimation of uncertainty in the determination of serum electrolytes (Na, K, Ca, Mg) by flame atomic absorption spectroscopy

AM García-Alegría, MG Canez-Carrasco, M Serna-Félix… - Mapan, 2018 - Springer
From a standardized and validated method to quantify serum electrolytes (Na, K, Ca and
Mg) by flame atomic absorption spectroscopy, combined relative uncertainty (CRSU) and …

Comparison of Headspace-Single Drop Microextraction and Dispersive Liquid–Liquid Microextraction for Determination of Benzene in Juice Drinks Containing …

M Kaykhaii, Z Hosseinbor, E Ghasemi - Chromatographia, 2016 - Springer
In this paper, a fast and effective headspace-single drop microextraction (HS-SDME) method
was applied for the determination of traces of benzene in juice drinks containing vitamin C …

Theoretical study of the sensor design strategy for colorimetric sensor array based on density functional theory

H Gu, Y Sun, S Li, X Huang, H Dai - Computational and Theoretical …, 2016 - Elsevier
The technique of colorimetric sensor array (CSA) is proved to be a novel and helpful method
to detect and determine the quality of food and beverages with simple, inexpensive, rapid …