Lyapunov based harmonic compensation and charging with three phase shunt active power filter in electrical vehicle applications

D Çelik - International Journal of Electrical Power & Energy …, 2022 - Elsevier
With the increasing proliferation of high-tech loads and electrical vehicle (EV) charging
stations, shunt active power filters (SAPFs) are contemplated to play a growingly substantial …

DSOGI-PLL with in-loop filter based solar grid interfaced system for alleviating power quality problems

A Ranjan, S Kewat, B Singh - IEEE Transactions on Industry …, 2020 - ieeexplore.ieee.org
This article deals with a dual second-order generalized integrator phase-locked loop
(DSOGI-PLL) with in-loop filter-based control approach for a single-stage, three-phase three …

An adaptive differentiation frequency based advanced reference current generator in grid-tied PV applications

PN Babu, R Peesapati, G Panda - IEEE Journal of Emerging …, 2019 - ieeexplore.ieee.org
In this article, an advanced reference current generator employing a combination of novel
dual multi-layer fifth-order generalized integrator and adaptive differentiation frequency …

A technical review on control strategies for active power filters

R Rajagopal, K Palanisamy… - … on Emerging Trends …, 2018 - ieeexplore.ieee.org
The ever-increasing use of harmonic causing loads in the power system has led to the
aggravation of many power quality issues mainly harmonics. The distortions triggered by …

A comprehensive approach to flexible LVRT strategies for inverter-based PPMs enhancing voltage support, overcurrent protection, and DC-link voltage quality

F Letaief, M Hamouda, MA Belaid, K Al-Haddad - IEEE Access, 2024 - ieeexplore.ieee.org
This paper focuses on enhancing the resilience of Power Park Modules (PPMs), connected
to the grid via power electronic units, under asymmetrical voltage sag conditions. We …

Performance improvement of shunt active power filter under variable grid frequency condition using complex coefficient filter‐frequency locked loop

AK Dubey, JP Mishra, A Kumar - International Journal of Circuit …, 2021 - Wiley Online Library
Synchronizing methodology for shunt active power filter (SAPF) based on the resonant
controller using generalized integrator (GI) in the stationary reference frame is of great …

Improved SHM‐PAM‐based five‐level CHB inverter to fulfil NRS 048‐2: 2003 grid code and to apply as shunt active power filter with tuned proportional‐resonant …

S Kundu, S Banerjee, S Bhowmick - IET Power Electronics, 2020 - Wiley Online Library
This study proposes a selective harmonic minimisation‐pulse amplitude modulation (SHM‐
PAM) technique utilising least number of switching based on optimised waveform pattern for …

DSOGI-PLL based solar grid interfaced system for alleviating power quality problems

A Ranjan, S Kewat, B Singh - 2019 National Power Electronics …, 2019 - ieeexplore.ieee.org
In this paper, a DSOGI-PLL (Dual Second Order Generalized Integrator Phase Locked Loop)
based control approach is proposed for single stage, 3P3W (Three Phase Three Wire) solar …

Delayed lms based adaptive control of pv-dstatcom system

I Hussain, RK Agarwal, B Singh - 2020 3rd International …, 2021 - ieeexplore.ieee.org
The dual-mode single-stage PV-DSTATCOM (Photovoltaic-Distributed Static Compensator)
system tied to the AC grid is presented using a DLMS (Delayed Least Mean Square) based …

Design of backstepping controller for a three-phase shunt active filter interfacing solar photovoltaic system to distribution grid

VN Jayasankar, U Vinatha - 2018 IEEE International …, 2018 - ieeexplore.ieee.org
This paper presents a controller for a three-phase four-leg shunt active power filter (SAPF),
interfacing solar photovoltaic system to distribution grid. The controller consists of a non …