The evolution of brachytherapy treatment planning

MJ Rivard, JLM Venselaar, L Beaulieu - Medical physics, 2009 - Wiley Online Library
Brachytherapy is a mature treatment modality that has benefited from technological
advances. Treatment planning has advanced from simple lookup tables to complex …

Pharmacogenomic testing in child and adolescent psychiatry: an evidence-based review

AM Wehry, L Ramsey, SE Dulemba… - Current problems in …, 2018 - Elsevier
Significant advances have been made in the application of pharmacogenomic testing for the
treatment of patients with psychiatric disorders. Over the past decade, a number of studies …

Report of the Task Group 186 on model‐based dose calculation methods in brachytherapy beyond the TG‐43 formalism: current status and recommendations for …

L Beaulieu, Å Carlsson Tedgren, JF Carrier… - Medical …, 2012 - Wiley Online Library
The charge of Task Group 186 (TG‐186) is to provide guidance for early adopters of model‐
based dose calculation algorithms (MBDCAs) for brachytherapy (BT) dose calculations to …

A dosimetric uncertainty analysis for photon‐emitting brachytherapy sources: report of AAPM Task Group No. 138 and GEC‐ESTRO

LA DeWerd, GS Ibbott, AS Meigooni, MG Mitch… - Medical …, 2011 - Wiley Online Library
This report addresses uncertainties pertaining to brachytherapy single‐source dosimetry
preceding clinical use. The International Organization for Standardization (ISO) Guide to the …

Dosimetry of 125I and 103Pd COMS eye plaques for intraocular tumors: Report of Task Group 129 by the AAPM and ABS

ST Chiu‐Tsao, MA Astrahan, PT Finger… - Medical …, 2012 - Wiley Online Library
Dosimetry of eye plaques for ocular tumors presents unique challenges in brachytherapy.
The challenges in accurate dosimetry are in part related to the steep dose gradient in the …

AAPM recommendations on medical physics practices for ocular plaque brachytherapy: report of task group 221

RM Thomson, KM Furutani, TW Kaulich… - Medical …, 2020 - Wiley Online Library
The American Association of Physicists in Medicine (AAPM) formed Task Group 221 (TG‐
221) to discuss a generalized commissioning process, quality management considerations …

Surface brachytherapy: joint report of the AAPM and the GEC‐ESTRO Task Group No. 253

RK Fulkerson, J Perez‐Calatayud, F Ballester… - Medical …, 2020 - Wiley Online Library
The surface brachytherapy Task Group report number 253 discusses the common treatment
modalities and applicators typically used to treat lesions on the body surface. Details of …

Guidelines by the AAPM and GEC‐ESTRO on the use of innovative brachytherapy devices and applications: Report of Task Group 167

R Nath, MJ Rivard, LA DeWerd, WA Dezarn… - Medical …, 2016 - Wiley Online Library
Although a multicenter, Phase III, prospective, randomized trial is the gold standard for
evidence‐based medicine, it is rarely used in the evaluation of innovative devices because …

AAPM task group report 303 endorsed by the ABS: MRI implementation in HDR brachytherapy—Considerations from simulation to treatment

J Prisciandaro, J Zoberi, G Cohen, Y Kim… - Medical …, 2022 - Wiley Online Library
The task group (TG) on magnetic resonance imaging (MRI) implementation in high‐dose‐
rate (HDR) brachytherapy (BT)—Considerations from simulation to treatment, TG 303, was …

Enhancements to commissioning techniques and quality assurance of brachytherapy treatment planning systems that use model‐based dose calculation algorithms a

MJ Rivard, L Beaulieu, F Mourtada - Medical physics, 2010 - Wiley Online Library
The current standard for brachytherapy dose calculations is based on the AAPM TG‐43
formalism. Simplifications used in the TG‐43 formalism have been challenged by many …