Design and performance of the GEMROC ASIC for 2-D readout of gas electron multiplier detectors

T Fiutowski, W Dąbrowski, B Mindur… - 2011 IEEE Nuclear …, 2011 - ieeexplore.ieee.org
Design and performance of the GEMROC ASIC for 2-D readout of gas electron multiplier
detectors Page 1 2011 IEEE Nuclear Science Symposium Conference Record N31-6 Design …

Performance of a Micro-Strip Gas Chamber for event wise, high rate thermal neutron detection with accurate 2D position determination

B Mindur, S Alimov, T Fiutowski, C Schulz… - Journal of …, 2014 - iopscience.iop.org
Abstract A two-dimensional (2D) position sensitive detector for neutron scattering
applications based on low-pressure gas amplification and micro-strip technology was built …

Development of an ASIC for 2-D readout of gas electron multiplier detectors

W Dąbrowski, T Fiutowski, B Mindur… - Proceedings of the …, 2011 - ieeexplore.ieee.org
This paper describes an Application Specific Integrated Circuit (ASIC) to be used for readout
of large area (30× 30cm 2) Gas Electron Multiplier (GEM) detector. The GEMROC design …

Development of very high rate and resolution neutron detectors with novel readout and DAQ hard-and software in DETNI

SS Alimov, A Borga, A Brogna… - 2008 IEEE Nuclear …, 2008 - ieeexplore.ieee.org
In the Joint Research Activity DETNI (DETectors for Neutron Instrumentation) of the FP6 EU
Integrated Infrastructure Initiative for Neutron Scattering and Muon Spectroscopy (NMI3) …

[图书][B] Detectors for quality assurance in hadrontherapy

DA Watts - 2014 - ddd.uab.cat
La terapia de hadrones es actualmente una realidad médica en oncología de radiación y
una técnica probada en la lucha contra el cáncer. Hoy en día, el uso de la terapia de …

[PDF][PDF] Design and performance of a system for two-dimensional readout of gas electron multiplier detectors for proton range radiography

P Wiącek, W Dąbrowski, T Fiutowski, B Mindur… - …, 2012 - bibliotekanauki.pl
The proton range radiography (PRR) technique being developed is expected to provide
significant improvements in precision delivery of the therapeutic dose in the hadron therapy …

FPGA-based algorithm for center of gravity calculation of clustered signals

AA Ushakov, B Mindur, T Fiutowski… - 2012 18th IEEE-NPSS …, 2012 - ieeexplore.ieee.org
The acquisition system for a two-dimensional neutron detector processes both detector
coordinates. The read-out electronics for each coordinate incorporates 4 ASICs which are …

[PDF][PDF] Preliminary test results on readout of a triple GEM detector using MSGCROC ASICs.

W Dąbrowski, T Fiutowski, B Mindur, P Wiącek - 2010 - indico.cern.ch
The goal for this work was to demonstrate performance of the MSGCROC ASIC applied to 2-
D readout of a GEM detector. The demonstrator system is built around a standard 10× 10 …

[PDF][PDF] LABORATORY COURSE ON POSITION SENSITIVE DETECTION TECHNIQUES

B Mindur, MCPADT Network - 2009 - Citeseer
The aim of the laboratory class is to setup and test a full chain of the readout electronics
used to detect signals generated in the detector by ionization particles. The electronics setup …