The creation of breast lesion models for mammographic virtual clinical trials: a topical review

A Van Camp, K Houbrechts, L Cockmartin… - Progress in …, 2023 - iopscience.iop.org
Simulated breast lesion models, including microcalcification clusters and masses, have
been used in several studies. Realistic lesion models are required for virtual clinical trials to …

Effect of image quality on calcification detection in digital mammography

LM Warren, A Mackenzie, J Cooke… - Medical …, 2012 - Wiley Online Library
Purpose: This study aims to investigate if microcalcification detection varies significantly
when mammographic images are acquired using different image qualities, including …

Image quality measurements and metrics in full field digital mammography: an overview

H Bosmans, AK Carton, F Rogge… - Radiation protection …, 2005 - academic.oup.com
This paper gives an overview of test procedures developed to assess the performance of full
field digital mammography systems. We make a distinction between tests of the individual …

Optimal beam quality selection in digital mammography

KC Young, JM Oduko, H Bosmans… - The British Journal of …, 2006 - academic.oup.com
An experimental method of determining the optimal beam quality for digital mammography
systems was applied to two systems (Fuji Profect and GE Senographe 2000D). The mean …

Evaluation of clinical image processing algorithms used in digital mammography

F Zanca, J Jacobs, C Van Ongeval, F Claus… - Medical …, 2009 - Wiley Online Library
Screening is the only proven approach to reduce the mortality of breast cancer, but
significant numbers of breast cancers remain undetected even when all quality assurance …

Comparison of the x-ray attenuation properties of breast calcifications, aluminium, hydroxyapatite and calcium oxalate

LM Warren, A Mackenzie, DR Dance… - Physics in Medicine & …, 2013 - iopscience.iop.org
Aluminium is often used as a substitute material for calcifications in phantom measurements
in mammography. Additionally, calcium oxalate, hydroxyapatite and aluminium are used in …

Grid removal and impact on population dose in full‐field digital mammography

G Gennaro, L Katz, H Souchay, R Klausz… - Medical …, 2007 - Wiley Online Library
The study purpose was to determine the impact of anti‐scatter grid removal on patient dose,
in full field digital mammography. Dose saving, phantom based, was evaluated with the …

Validation of simulation of calcifications for observer studies in digital mammography

LM Warren, FH Green, L Shrestha… - Physics in Medicine …, 2013 - iopscience.iop.org
Studies using simulated calcifications can be performed to measure the effect of different
imaging factors on calcification detection in digital mammography. The simulated …

An improved method for simulating microcalcifications in digital mammograms

F Zanca, DP Chakraborty, C Van Ongeval… - Medical …, 2008 - Wiley Online Library
The assessment of the performance of a digital mammography system requires an observer
study with a relatively large number of cases with known truth which is often difficult to …

The relationship between the attenuation properties of breast microcalcifications and aluminum

F Zanca, C Van Ongeval, N Marshall… - Physics in Medicine …, 2010 - iopscience.iop.org
Screening mammography is one of the most challenging radiological techniques and this is
partly due to the difficulty in detecting microcalcifications (MCs) against an anatomical …