Thermal-ageing characteristics of dry-type transformer epoxy composite insulation

Y Wang, C Feng, R Fei, Y Luo - High Performance Polymers, 2020 - journals.sagepub.com
To study the ageing characteristics of epoxy resin composite insulation in dry-type
transformers in high-temperature environments, glass fibre-reinforced epoxy resin samples …

Partial discharges in a cavity embedded in oil-impregnated paper: effect of electrical and thermal aging

MG Niasar, N Taylor, P Janus, X Wang… - … on Dielectrics and …, 2015 - ieeexplore.ieee.org
In this paper, the rapid aging due to Partial Discharge (PD) activity was investigated in
unaged and thermally aged oil-impregnated paper with a disk-shaped cavity between the …

A novel oil-immersed medium frequency transformer for offshore HVDC wind farms

M Kharezy, HR Mirzaei, Y Serdyuk… - … on Power Delivery, 2020 - ieeexplore.ieee.org
Offshore wind farms pose the challenge of transmission of produced energy in an economic
and effective way over long distances, justifying investments in High Voltage Direct Current …

An intelligent sensor for the ultra-high-frequency partial discharge online monitoring of power transformers

J Li, X Li, L Du, M Cao, G Qian - Energies, 2016 - mdpi.com
Ultra-high-frequency (UHF) partial discharge (PD) online monitoring is an effective way to
inspect potential faults and insulation defects in power transformers. The construction of …

Variability of the UHF signals generated by partial discharges in mineral oil

M Kunicki - Sensors, 2019 - mdpi.com
The paper presents the results of the analysis on the variability of the ultra-high frequency
(UHF) signals generated by partial discharges (PD) under the long-term AC voltage. Surface …

Void discharge behaviours as a function of cavity size and voltage waveform under very low‐frequency excitation

HVP Nguyen, BT Phung - High Voltage, 2018 - Wiley Online Library
Measurement of partial discharge (PD) is a vital method to assess the health of the electrical
insulation in high‐voltage power equipment. As diagnostic testing at very low frequency …

Partial discharge characteristics of uniform gap in oil-impregnated paper insulation under switching impulse voltage

J Deng, M Wang, Y Zhou, Z Zhou… - … on dielectrics and …, 2016 - ieeexplore.ieee.org
In comparison with the AC and DC working voltages, the effect of switching impulse voltage
on insulation is very different because of its fast-rising rate and large amplitude. This paper …

Comparison of PD detection methods for power transformers-their sensitivity and characteristics in time and frequency domain

Y Xu, W Liu, W Gao, X Zhang… - IEEE Transactions on …, 2016 - ieeexplore.ieee.org
Partial discharge (PD) detection is an important method for detecting defects in power
transformers, and several PD detection methods reported in literature have their respective …

Effects of impurities on surface discharges at synthetic ester/cellulose board

C Thirumurugan, GB Kumbhar… - IEEE Transactions on …, 2019 - ieeexplore.ieee.org
An electrical discharge that occurs at an oil/pressboard interface or pressboard surface is
called surface partial discharge. The surface discharge activity can cause irreversible …

Detection of high-energy ionizing radiation generated by electrical discharges in oil

D Zmarzły, T Boczar, P Fracz - IEEE Transactions on …, 2016 - ieeexplore.ieee.org
The article presents the results of multi-variant studies of high-energy ionizing radiation
emitted by electrical discharges occurring in oil insulating systems. The studies were …