Bariatric CT imaging: challenges and solutions

DM Fursevich, GM LiMarzi, MC O'Dell… - Radiographics, 2016 - pubs.rsna.org
The obesity epidemic in the adult and pediatric populations affects all aspects of health care,
including diagnostic imaging. With the increasing prevalence of obese and morbidly obese …

X-ray CT Metal Artifact Reduction Using Wavelet Domain Sparse Regularization

A Mehranian, MR Ay, A Rahmim… - IEEE transactions on …, 2013 - ieeexplore.ieee.org
X-ray computed tomography (CT) imaging of patients with metallic implants usually suffers
from streaking metal artifacts. In this paper, we propose a new projection completion metal …

Iterative image-domain ring artifact removal in cone-beam CT

X Liang, Z Zhang, T Niu, S Yu, S Wu, Z Li… - Physics in Medicine …, 2017 - iopscience.iop.org
Ring artifacts in cone beam computed tomography (CBCT) images are caused by pixel gain
variations using flat-panel detectors, and may lead to structured non-uniformities and …

Software architecture for multi-bed FDK-based reconstruction in X-ray CT scanners

M Abella, JJ Vaquero, A Sisniega, J Pascau… - Computer methods and …, 2012 - Elsevier
Most small-animal X-ray computed tomography (CT) scanners are based on cone-beam
geometry with a flat-panel detector orbiting in a circular trajectory. Image reconstruction in …

A ring artifact correction method: Validation by micro-CT imaging with flat-panel detectors and a 2D photon-counting detector

ME Eldib, M Hegazy, YJ Mun, MH Cho, MH Cho… - Sensors, 2017 - mdpi.com
We introduce an efficient ring artifact correction method for a cone-beam computed
tomography (CT). In the first step, we correct the defective pixels whose values are close to …

A variation-based ring artifact correction method with sparse constraint for flat-detector CT

L Yan, T Wu, S Zhong, Q Zhang - Physics in Medicine & Biology, 2016 - iopscience.iop.org
The reconstructed slice quality of flat-detector computed tomography (CT) is often disturbed
by concentric-ring artifacts. Since concentric rings in CT slices appear as straight stripes …

Removing ring artefacts for photon-counting detectors using neural networks in different domains

W Fang, L Li, Z Chen - IEEE access, 2020 - ieeexplore.ieee.org
The development of energy-resolving photon-counting detectors provides a new approach
for obtaining spectral information in computed tomography. However, the responses of …

Detector shifting and deep learning based ring artifact correction method for low‐dose CT

Y Liu, C Wei, Q Xu - Medical Physics, 2023 - Wiley Online Library
Background In x‐ray computed tomography (CT), the gain inconsistency of detector units
leads to ring artifacts in the reconstructed images, seriously destroys the image structure …

Ring artifacts removal from synchrotron CT image slices

Z Wei, S Wiebe, D Chapman - Journal of Instrumentation, 2013 - iopscience.iop.org
Ring artifacts can occur in reconstructed images from x-ray Computerized Tomography (CT)
as full or partial concentric rings superimposed on the scanned structures. Due to the data …

Ring artifact correction using detector line-ratios in computed tomography

Y Kim, J Baek, D Hwang - Optics express, 2014 - opg.optica.org
Ring artifacts in computed tomography (CT) images degrade image quality and obscure the
true shapes of objects. While several correction methods have been developed, their …