A model for the energy and angular distribution of x rays emitted from an x‐ray tube. Part II. Validation of x‐ray spectra from 20 to 300 kV

A Omar, P Andreo, G Poludniowski - Medical Physics, 2020 - Wiley Online Library
Purpose To present and validate a complete x‐ray emission model (bremsstrahlung and
characteristic x‐ray emission) for the energy range 20–300 kV. Methods An analytical x‐ray …

Improving small animal cone beam CT resolution by mitigating x-ray focal spot induced blurring via deconvolution

X Hu, Y Zhong, Y Huang, C Shen… - Physics in Medicine & …, 2022 - iopscience.iop.org
Objective. Modern preclinical small animal radiation platforms utilize cone beam
computerized tomography (CBCT) for image guidance and experiment planning purposes …

A molybdenum nanostructured-film target for tunable x-ray sources: surface-structure controllable preparing and radiation intensity selecting

J Shi, Y Shen, A Cheng, Y Jiang, H Zhang, T Cui… - Physica …, 2023 - iopscience.iop.org
Tunable x-ray sources have attracted interest due to providing selective focal spots and
radiation intensities for different specific uses. Surface-structure of the anode target has a …

Investigating focal spot position drift in a mobile imaging system equipped with a monobloc‐based x‐ray generator

IM Messner, P Keuschnigg, B Stöllinger… - Medical …, 2024 - Wiley Online Library
Background Misalignment or double‐contouring artifacts can appear in high‐resolution 3D
cone beam computed tomography (CBCT) images, potentially indicating geometric accuracy …

Monte Carlo Modelling Of External Photon Beams In Radiotherapy

F Verhaegen - Monte Carlo Techniques in radiation therapy, 2021 - taylorfrancis.com
This chapter discusses the Monte Carlo modelling of photon beams and the one of electron
beams, while others will deal with hadron beams. One of the most frequent, important uses …

[HTML][HTML] Single crystalline molybdenum nanostructure for generating reflective micro-focal spot X-rays: Structure-controllable preparation and characteristic-selectable …

J Shi, Y Shen, T Cui, A Cheng, F Liu, R Zhan, S Tang… - Results in Physics, 2024 - Elsevier
The use of properly designed nanostructured anode targets enables direct generation of
high performance X-rays. In particular, this scheme has attracted widespread research …

Impact of microstructure on the performance of WRe10 conversion layers for stationary and rotating anodes

M Siller, N Bostrom, P Bogust, J Schatte… - International Journal of …, 2023 - Elsevier
The focal track of high-performance rotating anodes withstands extreme temperatures,
thermal shock, and thermal fatigue during the operation of X-ray tubes. Overloading the focal …

[HTML][HTML] Efficient full Monte Carlo modelling and multi-energy generative model development of an advanced X-ray device

H Fuchs, L Zimmermann, N Reisz, M Zeilinger… - … für Medizinische Physik, 2023 - Elsevier
Monte Carlo (MC) simulations of X-ray image devices require splitting the simulation into two
parts (ie the generation of x-rays and the actual imaging). The X-ray production remains …

[HTML][HTML] Analysis of the off-focal source in transmission geometry X-ray systems

K Steklova, AL Fielding, LJ Beeching… - Nuclear Instruments and …, 2024 - Elsevier
For X-ray tubes in lab based computed micro-tomography systems, off-focal X rays are those
emitted from the source but not produced at the primary focal spot of the electron beam …

[PDF][PDF] A study of off-focal radiation in transmission geometry x-ray sources

K Steklova, A Fielding, L Beeching, AP Sheppard… - Proc. 12th Conference …, 2023 - ndt.net
Off-focal x rays are an undesirable feature in industrial and medical x-ray computed-
tomography scanners that contributes the effects of a large defocused source. They lead to …