A wavelet-based transformer differential protection with differential current transformer saturation and cross-country fault detection

RP Medeiros, FB Costa - IEEE Transactions on Power Delivery, 2017 - ieeexplore.ieee.org
The current transformer (CT) saturation phenomenon has been one of the main problems for
the power transformer differential protection, leading to incorrect current measurements and …

Distance protection of lines connected to induction generator-based wind farms during balanced faults

A Hooshyar, MA Azzouz… - IEEE Transactions on …, 2014 - ieeexplore.ieee.org
Wind farms (WFs) are increasingly integrated with high-voltage (HV) grids, for which
distance relaying is normally the protection of choice. This paper reveals some serious …

[图书][B] Protective relaying of power systems using mathematical morphology

QH Wu, Z Lu, T Ji - 2009 - books.google.com
Page 1 QH Wu Z. Lu⚫ TY Ji power systems Protective Relaying of Power Systems Using
Mathematical Morphology Springer Page 2 Power Systems Page 3 QH Wu Z. Lu· TY Ji • …

Fast discrimination of transformer magnetizing current from internal faults: An extended Kalman filter-based approach

F Naseri, Z Kazemi, MM Arefi… - IEEE Transactions on …, 2017 - ieeexplore.ieee.org
Differential protection is the most common type of protection in power transformers.
However, inrush current due to transformer energization may appear as fault current to the …

Current-transformer saturation compensation for transformer differential relays

E Hajipour, M Vakilian… - IEEE Transactions on …, 2015 - ieeexplore.ieee.org
Current-transformer (CT) saturation threatens accurate discrimination between internal fault
current and magnetizing inrush current of a transformer and endangers the proper operation …

Correction of saturated current transformers secondary current using ANNs

H Khorashadi-Zadeh… - IEEE Transactions on …, 2005 - ieeexplore.ieee.org
Current transformers (CTs) provide instrument-level current signals to meters and protective
relays. Protective relays' accuracy and performance are directly related to steady-state and …

Fast detection and compensation of current transformer saturation using extended Kalman filter

F Naseri, Z Kazemi, E Farjah… - IEEE Transactions on …, 2019 - ieeexplore.ieee.org
In this paper, an efficient method based on the Kalman filter (KF) theory is proposed for fast
and accurate detection and compensation of current transformer (CT) saturation. During the …

直流偏磁条件下电流互感器的传变特性

李长云, 李庆民, 李贞, 孙秋芹 - 中国电机工程学报, 2010 - epjournal.csee.org.cn
直流偏磁现象会改变电磁式电流互感器(current transformer, CT) 的传变特性,
影响继电保护可靠性和电能计量的公平性. 通过建立等效电路模型, 利用电磁关系方程推导剩磁 …

Compensation of the current-transformer saturation effects for digital relays

FB Ajaei, M Sanaye-Pasand… - … on Power Delivery, 2011 - ieeexplore.ieee.org
A current transformer (CT) is accurately modeled for representation of the CT saturation
effects on digital protective relays. Simulation studies performed in the PSCAD/EMTDC …

Phasor estimation in the presence of DC offset and CT saturation

SR Nam, JY Park, SH Kang… - IEEE transactions on …, 2009 - ieeexplore.ieee.org
A hybrid algorithm for phasor estimation is proposed that is immune to DC offset and current