Fluorescent nuclear track detectors–review of past, present and future of the technology

M Akselrod, J Kouwenberg - Radiation Measurements, 2018 - Elsevier
Abstract Fluorescent Nuclear Track Detector technology is a passive luminescent integrating
detector technology having important advantages in measuring neutrons, heavy ions and …

Fluorescent nuclear track detectors as a tool for ion-beam therapy research

S Greilich, JM Osinga, M Niklas, FM Lauer… - Radiation …, 2013 - Elsevier
Fluorescent nuclear track detectors based on Al 2 O 3: C, Mg with their excellent efficiency
for detection of heavy charged particles and full 3D information from laser scanning …

High resolution charge spectroscopy of heavy ions with FNTD technology

JA Bartz, S Kodaira, M Kurano, N Yasuda… - Nuclear Instruments and …, 2014 - Elsevier
This paper is focused on the improvement of the heavy charge particle charge resolution of
Fluorescent Nuclear Track Detector (FNTD) technology. Fluorescent intensity of individual …

Fluence-based dosimetry of proton and heavier ion beams using single track detectors

G Klimpki, H Mescher, MS Akselrod… - Physics in Medicine …, 2016 - iopscience.iop.org
Due to their superior spatial resolution, small and biocompatible fluorescent nuclear track
detectors (FNTDs) open up the possibility of characterizing swift heavy charged particle …

Characteristics of fluorescent nuclear track detection with Ag+-activated phosphate glass

S Kodaira, T Kusumoto, H Kitamura, Y Yanagida… - Radiation …, 2020 - Elsevier
Silver-activated phosphate glass (Ag+-glass), which is commonly employed as a
radiophotoluminscence (RPL) dosimeter, was applied as a fluorescent nuclear track …

Subcellular spatial correlation of particle traversal and biological response in clinical ion beams

M Niklas, A Abdollahi, MS Akselrod, J Debus… - International Journal of …, 2013 - Elsevier
Purpose To report on the spatial correlation of physical track information (fluorescent nuclear
track detectors, FNTDs) and cellular DNA damage response by using a novel hybrid …

[HTML][HTML] Engineering cell-fluorescent ion track hybrid detectors

M Niklas, S Greilich, C Melzig, MS Akselrod, J Debus… - Radiation …, 2013 - Springer
Background The lack of sensitive biocompatible particle track detectors has so far limited
parallel detection of physical energy deposition and biological response. Fluorescent …

Alpha particle spectrometry in fluorescent nuclear track detectors with an automatic 3D track reanalysis algorithm

J Hu, T Kusumoto, M Janik, S Kodaira - Radiation Measurements, 2024 - Elsevier
The main obstacle to applying aluminum oxide doped with carbon and magnesium (Al 2 O
3: C, Mg)-based fluorescent nuclear track detectors (FNTDs) in radionuclide therapy with …

Ion track reconstruction in 3D using alumina-based fluorescent nuclear track detectors

M Niklas, JA Bartz, MS Akselrod… - Physics in Medicine …, 2013 - iopscience.iop.org
Fluorescent nuclear track detectors (FNTDs) based on Al 2 O 3: C, Mg single crystal
combined with confocal microscopy provide 3D information on ion tracks with a resolution …

Intensity threshold variation method in the post-irradiation analysis of Fluorescent Nuclear Track Detectors for neutron dosimetry

A Becker, O Jäkel, J Vedelago - Radiation Physics and Chemistry, 2022 - Elsevier
Abstract Fluorescent Nuclear Track Detectors (FNTDs) are biocompatible passive detectors
and a promising tool for neutron dosimetry applications, such as in-phantom measurements …