Simple and systematic LCL filter design for three-phase grid-connected power converters

MB Said-Romdhane, MW Naouar, IS Belkhodja… - … and Computers in …, 2016 - Elsevier
The objective of this paper is to propose a simple, less intuitive and systematic design
methodology for the tuning of LCL filter parameters. The considered design methodology …

Design of LCL Filter for Grid-Interfaced PV System Based on Cost Minimization

C Poongothai, K Vasudevan - IEEE Transactions on Industry …, 2018 - ieeexplore.ieee.org
Many research works report the use of LCL filters for grid-interfaced PV systems. Indiscreet
selection of passive LCL filter parameters may result in poor filtering and increased power …

Improved pr control strategy for an lcl three-phase grid-connected inverter based on active damping

Y Li, J Zhang, Z Hao, P Tian - Applied Sciences, 2021 - mdpi.com
Featured Application The controller of a three-phase grid-connected inverter is studied and
improved, which provides support for the independent control of power and the design of the …

Comprehensive optimization of ZVS variable frequency control for SiC/Si HANPC Converter

Z Cai, Y Du, J Su, X Yang, Y Shi… - IEEE Transactions on …, 2023 - ieeexplore.ieee.org
The growing demand for high-efficiency power converters with silicon carbide (SiC) devices
at high switching frequencies has fueled an interest in non-auxiliary circuit-based soft …

Analytical closed‐form expressions of DC current ripple for three‐level neutral point clamped inverters with space‐vector pulse‐width modulation

L Kai, L Mengshu, L Zhengfeng… - IET Power …, 2016 - Wiley Online Library
The current ripple of the DC bus is a key factor for the DC‐link capacitor parameter design of
three‐level neutral point clamped (NPC) inverters. It directly affects the selection of capacitor …

LCL-filter design for grid-connected inverter to suppress grid-induced low-order current harmonics

J Xu, S Xie, J Kan - 2015 IEEE Energy Conversion Congress …, 2015 - ieeexplore.ieee.org
For grid-connected inverter, an LCL-type filter is widely used to suppress switching
harmonics, and the capacitor current feedback is used to suppress the LCL resonance. In …

[HTML][HTML] Diseño optimizado del conjunto filtro-controlador de un inversor para mejorar su integración a red

JD Mina-Antonio, E Miramón-Juárez… - Ingeniería …, 2022 - scielo.org.mx
Este trabajo aborda el diseño optimizado del filtro LCL y el controlador del lazo interno de
corriente (PI) para un inversor trifásico de puente completo de un sistema de generación …

Optimized design of the set filter-controller of an inverter in order to improve its grid integration

JD Mina-Antonio, E Miramón-Juárez… - Ingeniería …, 2022 - scielo.org.mx
MINA-ANTONIO, Jesús Darío; MIRAMON-JUAREZ, Eduardo; HERNANDEZ-MARTINEZ,
Oscar y SABIDO-BORGES, Miguel Francisco. Optimized design of the set filter-controller of …

Research on the robustness of lcl filter based on fractional order control technology

C He, H Xiong, H Zhang - 2021 IEEE 5th Advanced Information …, 2021 - ieeexplore.ieee.org
This paper presents a scheme for the robust optimal design of LCL filters. Based on the
background of the research on LCL parameter optimization design for grid-connected …

Study on Power Supply Mode of Distribution Network Based on Three-phase to Single-phase AC_DC_AC Converter

Z LIANG, Z Xiangyu, LIU Wei… - 2019 IEEE 8th …, 2019 - ieeexplore.ieee.org
With the development of distribution network, the three-phase unbalance caused by
increasingly complex loads affects the safety and economic operation of the power grid. For …