Detection of spontaneous pulse using the acceleration signals acquired from CPR feedback sensor in a porcine model of cardiac arrest

L Wei, G Chen, Z Yang, T Yu, W Quan, Y Li - PloS one, 2017 - journals.plos.org
Background Reliable detection of return of spontaneous circulation with minimal
interruptions of chest compressions is part of high-quality cardiopulmonary resuscitation …

[HTML][HTML] A pilot study of high frequency accelerometry-based sedation and agitation monitoring in critically ill patients

M Weeden, N Desai, S Sriram, MS Palaniswami… - Critical Care and …, 2020 - Elsevier
Objective: The degree of sedation or agitation in critically ill patients is typically assessed
with the Richmond Agitation and Sedation Scale (RASS). However, this approach is …

Kinetic analysis of cardiac compressions during cardiopulmonary resuscitation

YW Kim, KC Cha, YS Kim, YS Cha, H Kim, KH Lee… - Journal of Critical …, 2019 - Elsevier
Purpose Little is known about the dynamics of cardiac compression during cardiopulmonary
resuscitation (CPR). The purpose of this study was to investigate the dynamics of chest …

Design and implementation of a cardiac arrest supporting system using wearable device

JS Jang, SJ Lee, KI Lee, TR Lee - Journal of Digital Convergence, 2017 - koreascience.kr
Cardiac arrest is a serious intensive emergency disease that causes death within less than
several minutes by depriving the body and brain of blood supply. Survival rate of cardiac …

Development of an Objective Measurement System for Quality Assessment of Chest Compressions during CPR

IICN Jorge - 2021 - search.proquest.com
Out-of-hospital cardiac arrest is the third leading cause of death in Europe, with an
associated survival rate of only 8%. A rapid and effective intervention of the community with …

Recognition of abnormal chest compression depth using one-dimensional convolutional neural networks

L Zhao, Y Bao, Y Zhang, R Ye, A Zhang - Sensors, 2021 - mdpi.com
When the displacement of an object is evaluated using sensor data, its movement back to
the starting point can be used to correct the measurement error of the sensor. In medicine …

Development of an Objective Measurement System for Quality Assessment of Chest Compressions

I Jorge, C Sá-Couto, A Nicolau - 2022 17th Iberian Conference …, 2022 - ieeexplore.ieee.org
High-quality cardiopulmonary resuscitation (CPR) has a critical impact on the survival of
sudden cardiac arrest victims. The use of automated devices to support CPR training …

[图书][B] Internet of Things-Based Collaborative Position-Sensing Systems for Cardiopulmonary Resuscitation and Indoor Localization

H Chen - 2022 - search.proquest.com
The ubiquitous IoT devices have promoted the growth of applications that require target
positioning. While precise positioning remains a challenge for IoT devices, existing methods …

Design of a new feedback device for cardiopulmonary resuscitation

BT Lhoucine, E Elmaati, L Aissam… - 2018 IEEE 4th …, 2018 - ieeexplore.ieee.org
Several technical approaches were evaluated to improve the performance of rescuers, but to
our knowledge no attempt was realized to develop a feedback device to supervise the …

[PDF][PDF] A classification method for judging the depth of chest compression based on CNN

Z Liang, B Yu, Y Ruidong, Z Aijuan, Z Yu - pdfs.semanticscholar.org
The displacement can be calculated based on the integrated value of the acceleration signal
waveform obtained by the acceleration sensor or gyroscope. However, this method is not …