Fast and robust 3D electrical capacitance tomography

Y Li, DJ Holland - Measurement Science and Technology, 2013 - iopscience.iop.org
Electrical capacitance tomography (ECT) is well established for 2D imaging of multiphase
flow. Increasingly, ECT is now being used to image in 3D. In this paper we examine the …

Architecture of EVT4 data acquisition system for electrical capacitance tomography

J Kryszyn, P Wróblewski, M Stosio, D Wanta… - Measurement, 2017 - Elsevier
An EVT4 system for electrical capacitance tomography, which enables fast data acquisition
and a high frame rate for dynamic process imaging, is presented. A hardware architecture …

A comparative study between electrical capacitance tomography and time-resolved X-ray tomography

C Rautenbach, RF Mudde, X Yang, MC Melaaen… - Flow Measurement and …, 2013 - Elsevier
Modern day tomographs enable the research community to investigate the internal flow
behavior of a fluidized bed by non-invasive methods that partially overcome the opaque …

Application of twin-plane ECT sensor for identification of the internal imperfections inside concrete beams

K Grudzien, Z Chaniecki, A Romanowski… - 2016 IEEE …, 2016 - ieeexplore.ieee.org
The main purpose of this paper is to investigate application of special construction of
Electrical Capacitance Tomography (ECT) sensor to concrete beams internal homogeneity …

Investigations into the measurement sensitivity distribution of coplanar capacitive imaging probes

X Yin, DA Hutchins, G Chen, W Li - Ndt & E International, 2013 - Elsevier
In this paper, the measurement sensitivity distributions of coplanar capacitive imaging
probes are studied. An equation to calculate measurement sensitivity distribution of a …

Shape based reconstruction of experimental data in 3D electrical capacitance tomography

R Banasiak, M Soleimani - NDT & E International, 2010 - Elsevier
Electrical capacitance tomography (ECT) is a non-invasive and non-destructive imaging
technique that uses electrical capacitance measurement at the periphery of an object. The …

Optimizing the geometry of three-dimensional electrical capacitance tomography sensors

Y Li, DJ Holland - IEEE sensors Journal, 2014 - ieeexplore.ieee.org
Electrical capacitance tomography (ECT) is well established for 2D imaging of multiphase
distributions. Increasingly, ECT is being used to image in 3D. In this paper, we discuss the …

Evaluation of the electrical capacitance tomography system for measurement using 3d sensor

J Kryszyn, D Wanta, WT Smolik - Informatyka, Automatyka, Pomiary w …, 2019 - ph.pollub.pl
Further tests of EVT4 data acquisition system for electrical capacitance tomography are
presented. The modular system, which can have up to 32 channels with an individual …

Statistical diagnosis of a gas–solid fluidized bed using electrical capacitance tomography

C Rautenbach, MC Melaaen, BM Halvorsen - International journal of …, 2013 - Elsevier
Fluidization experiments were performed using several particle size distributions of
spherical glass particles, ranging from Geldart B to D. An Electrical Capacitance …

Crack detection in dielectric objects using electrical capacitance tomography imaging

M Soleimani, VJ Stewart… - Insight-Non-Destructive …, 2011 - ingentaconnect.com
Dielectric materials are becoming widely used because of their versatility and low cost.
Examples include carbon fibre, glass reinforced plastic, polymers and ceramics. These …