[HTML][HTML] Secondary outcomes of lens and cataract surgery: More than just “best-corrected visual acuity”

I Hecht, P Kanclerz, R Tuuminen - Progress in Retinal and Eye Research, 2023 - Elsevier
Most studies evaluating cataract surgery focus on the primary outcome of early, central, best-
corrected visual acuity. However, cataract surgery and intraocular lens (IOL) design have …

A review of late intraocular lens opacifications

P Kanclerz, TM Yildirim… - Current Opinion in …, 2021 - journals.lww.com
Several reports on late IOL opacifications have been published in recent years. In some
cases, particularly in glistening, the development of the opacifications might be related to …

Mid-term and long-term clinical assessments of a new 1-piece hydrophobic acrylic IOL with hydroxyethyl methacrylate

T Oshika, Y Fujita, M Inamura… - Journal of Cataract & …, 2020 - journals.lww.com
Purpose: To investigate the clinical outcomes after implantation of a new hydrophobic acrylic
intraocular lens (IOL) with hydroxyethyl methacrylate (HEMA) at 1 year and 9 years …

Visual and refractive outcomes and glistenings occurrence after implantation of 2 hydrophobic acrylic aspheric monofocal IOLs

N Stanojcic, D O'Brart, C Hull, V Wagh… - Journal of Cataract & …, 2020 - journals.lww.com
Purpose: To compare the Clareon IOL with the Tecnis PCB00 IOL in terms of visual
performance, refractive outcomes, glistenings occurrence, and quality-of-life outcomes …

Clinical and material degradations of intraocular lenses: a review

N Stanojcic, C Hull, DPS O'Brart - European Journal of …, 2020 - journals.sagepub.com
Purpose: To review the published scientific literature concerning clinical and material
degradations of intraocular lenses after implantation in cataract surgery. Methods: A search …

[HTML][HTML] Quantitative evaluation of microvacuole formation in five intraocular lens models made of different hydrophobic materials

TM Yildirim, SK Schickhardt, Q Wang, E Friedmann… - PLoS …, 2021 - journals.plos.org
In this laboratory study, we assessed the resistance to microvacuole (glistening) formation in
hydrophobic intraocular lenses (IOLs). Glistenings were induced in five lenses each of five …

Glistening on intraocular lenses: A review

JI Fernández-Vigo, MTS González-Peramato… - Archivos de la Sociedad …, 2023 - Elsevier
The glistening in intraocular lenses (IOLs) is a phenomenon in which tiny water-filled
microvacuoles (MVs) form within the IOL material, causing light to scatter and create a …

[HTML][HTML] Three-year multinational clinical study on an aspheric hydrophobic acrylic intraocular lens

RMMA Nuijts, U Bhatt, MA Nanavaty… - Journal of Cataract & …, 2023 - journals.lww.com
Purpose: To present the results of a study investigating the 3-year effectiveness and safety of
the Clareon single-piece intraocular lens (IOL). Setting: 19 multinational sites. Design …

[HTML][HTML] Objective Classification of Glistening in Implanted Intraocular Lenses Using Optical Coherence Tomography: Proposal for a New Classification and Grading …

JI Fernández-Vigo, B Burgos-Blasco… - Journal of Clinical …, 2023 - mdpi.com
Purpose: To propose a classification of the glistening in intraocular lenses (IOL) using swept-
source optical coherence tomography (SS-OCT) by means of a simple, objective and …

3D monitoring of the microphase separations inside the intraocular lens

Y Mao, X Liang, J Zhao, L Jiang, Q Liang, T Ngai… - Acta Biomaterialia, 2024 - Elsevier
Glistenings often occur after implanting the intraocular lens (IOL) due to the formation of
numerous microvacuoles (MVs) and may lead to deterioration of vision quality. Previous …