Virtual clinical trials in medical imaging: a review

E Abadi, WP Segars, BMW Tsui… - Journal of Medical …, 2020 - spiedigitallibrary.org
The accelerating complexity and variety of medical imaging devices and methods have
outpaced the ability to evaluate and optimize their design and clinical use. This is a …

MRI‐related heating of implants and devices: a review

L Winter, F Seifert, L Zilberti, M Murbach… - Journal of Magnetic …, 2021 - Wiley Online Library
During an MRI scan, the radiofrequency field from the scanner's transmit coil, but also the
switched gradient fields, induce currents in any conductive object in the bore. This makes …

7 Tesla and beyond: advanced methods and clinical applications in magnetic resonance imaging

T Platt, ME Ladd, D Paech - Investigative radiology, 2021 - journals.lww.com
Ultrahigh magnetic fields offer significantly higher signal-to-noise ratio, and several
magnetic resonance applications additionally benefit from a higher contrast-to-noise ratio …

Improving safety of MRI in patients with deep brain stimulation devices

A Boutet, CT Chow, K Narang, GJB Elias, C Neudorfer… - Radiology, 2020 - pubs.rsna.org
MRI is a valuable clinical and research tool for patients undergoing deep brain stimulation
(DBS). However, risks associated with imaging DBS devices have led to stringent …

Safety and image quality at 7T MRI for deep brain stimulation systems: Ex vivo study with lead-only and full-systems

B Bhusal, J Stockmann, B Guerin, A Mareyam, J Kirsch… - Plos one, 2021 - journals.plos.org
Ultra-high field MRI at 7 T can produce much better visualization of sub-cortical structures
compared to lower field, which can greatly help target verification as well as overall …

A review of parallel transmit arrays for ultra-high field MR imaging

CH Choi, A Webb, S Orzada… - IEEE Reviews in …, 2023 - ieeexplore.ieee.org
Parallel transmission (pTX) techniques are required to tackle a number of challenges, eg,
the inhomogeneous distribution of the transmit field and elevated specific absorption rate …

Patient's body composition can significantly affect RF power deposition in the tissue around DBS implants: ramifications for lead management strategies and MRI field …

B Bhusal, B Keil, J Rosenow… - Physics in Medicine …, 2021 - iopscience.iop.org
Patients with active implants such as deep brain stimulation (DBS) devices have limited
access to magnetic resonance imaging (MRI) due to risks associated with RF heating of …

Solving the time-and frequency-multiplexed problem of constrained radiofrequency induced hyperthermia

A Kuehne, E Oberacker, H Waiczies, T Niendorf - Cancers, 2020 - mdpi.com
Targeted radiofrequency (RF) heating induced hyperthermia has a wide range of
applications, ranging from adjunct anti-cancer treatment to localized release of drugs. Focal …

Wirelessly interfacing sensor‐equipped implants and MR scanners for improved safety and imaging

B Silemek, F Seifert, J Petzold, R Brühl… - Magnetic …, 2023 - Wiley Online Library
Purpose To investigate a novel reduced RF heating method for imaging in the presence of
active implanted medical devices (AIMDs) which employs a sensor‐equipped implant that …

Rapid safety assessment and mitigation of radiofrequency induced implant heating using small root mean square sensors and the sensor matrix Qs

B Silemek, F Seifert, J Petzold… - Magnetic resonance …, 2022 - Wiley Online Library
Purpose Rapid detection and mitigation of radiofrequency (RF)‐induced implant heating