A review of dose calculation approaches with cone beam CT in photon and proton therapy

V Giacometti, AR Hounsell, CK McGarry - Physica Medica, 2020 - Elsevier
Background and purpose The use of cone beam computed tomography (CBCT) for
performing dose calculations in radiation therapy has been widely investigated as it could …

Spatial descriptions of radiotherapy dose: normal tissue complication models and statistical associations

MA Ebert, S Gulliford, O Acosta… - Physics in Medicine …, 2021 - iopscience.iop.org
For decades, dose-volume information for segmented anatomy has provided the essential
data for correlating radiotherapy dosimetry with treatment-induced complications. Dose …

[HTML][HTML] A convolution neural network for higher resolution dose prediction in prostate volumetric modulated arc therapy

I Sumida, T Magome, IJ Das, H Yamaguchi, H Kizaki… - Physica Medica, 2020 - Elsevier
Purpose This study aims to investigate the feasibility of using convolutional neural networks
to predict an accurate and high resolution dose distribution from an approximated and low …

[HTML][HTML] Dosimetric and radiobiological comparison in head-and-neck radiotherapy using JO-IMRT and 3D-CRT

DT Tai, LT Oanh, PH Phuong, A Sulieman… - Saudi Journal of …, 2022 - Elsevier
Introduction Dosimetric and radiobiological evaluations for the Jaws-only Intensity-
modulated radiotherapy (JO-IMRT) technique for head and neck jaws-only intensity …

[PDF][PDF] 计算网格大小对脑肿瘤立体定向放射治疗剂量学的影响

刘力闽, 陈馨薇, 罗静, 康盛伟, 黎杰, 王培… - 中国医疗设备, 2022 - cs.china-cmd.org
目的比较剂量计算网格(Dose Calculation Grid Size, DCGS) 大小对基于容积旋转弧形调强放疗
技术(Volumetric Modulate Arc Therapy, VMAT) 的脑肿瘤立体定向放疗(Steretactic …

[PDF][PDF] AXB 算法与AAA 算法在宫颈癌VMAT 放射治疗中的剂量学差异

张向学, 张谦, 孙春堂, 尹如铁, 李清丽, 陈亚正 - 中国医疗设备, 2022 - cs.china-cmd.org
目的分析和比较宫颈癌术后容积旋转调强放射治疗(Volumetric Intensity-Modulated Arc
Therapy, VMAT) 中光子剂量算法(Acuros External Beam Algorithm, AXB) …

Impact of acuros XB algorithm in deep-inspiration breath-hold (DIBH) respiratory techniques used for the treatment of left breast cancer

L Kumar, V Kishore, M Bhushan… - Reports of Practical …, 2020 - journals.viamedica.pl
Impact of acuros XB algorithm in deep-inspiration breath-hold (DIBH) respiratory techniques
used for the treatment of left breas Page 1 Reports of Practical Oncology and Radiotherapy 25 …

[PDF][PDF] VMAT 计划中计算网格尺寸对宫颈癌放疗剂量的影响

魏敏, 陈长建, 葛双, 郗会珍, 程锦绣, 魏鹏… - 中国医疗 …, 2022 - cs.china-cmd.org
目的探究在Monaco 计划系统中使用容积弧形调强放射治疗(Volumetric Modulated Arc
Therapy, VMAT) 计划时计算网格尺寸对于宫颈癌病例优化的影响. 方法选择在我院Monaco …

[HTML][HTML] 基于Varian 加速器海马保护全脑放疗剂量学技术比较

解昕, 李亮, 范雪梅, 徐钰梅, 沙冠辰, 刘肖肖 - 中国辐射卫生, 2021 - html.rhhz.net
目的通过比较Varian 加速器共面动态调强dIMRT 与共面VMAT 计划在海马保护全脑放疗(
WBRT) 中剂量学差异, 为临床放疗计划选择提供一种依据. 方法10 例海马保护WBRT 患者 …

Dose Super-Resolution in Prostate Volumetric Modulated Arc Therapy Using Cascaded Deep Learning Networks

DS Shin, KH Kim, SW Kang, SH Kang, JS Kim… - Frontiers in …, 2020 - frontiersin.org
Purpose This study proposes a cascaded network model for generating high-resolution
doses (ie, a 1 mm grid) from low-resolution doses (ie,≥ 3 mm grids) with reduced …