Validity and reliability of wearable sensors for joint angle estimation: A systematic review

I Poitras, F Dupuis, M Bielmann, A Campeau-Lecours… - Sensors, 2019 - mdpi.com
Motion capture systems are recognized as the gold standard for joint angle calculation.
However, studies using these systems are restricted to laboratory settings for technical …

Use of wearable sensor technology in gait, balance, and range of motion analysis

S Díaz, JB Stephenson, MA Labrador - Applied Sciences, 2019 - mdpi.com
More than 8.6 million people suffer from neurological disorders that affect their gait and
balance. Physical therapists provide interventions to improve patient's functional outcomes …

Measurement of upper limb range of motion using wearable sensors: a systematic review

CP Walmsley, SA Williams, T Grisbrook, C Elliott… - Sports medicine …, 2018 - Springer
Background Wearable sensors are portable measurement tools that are becoming
increasingly popular for the measurement of joint angle in the upper limb. With many brands …

A comprehensive analysis of the validity and reliability of the perception neuron studio for upper-body motion capture

Y Wu, K Tao, Q Chen, Y Tian, L Sun - Sensors, 2022 - mdpi.com
The Perception Neuron Studio (PNS) is a cost-effective and widely used inertial motion
capture system. However, a comprehensive analysis of its upper-body motion capture …

Validity of wearable sensors at the shoulder joint: Combining wireless electromyography sensors and inertial measurement units to perform physical workplace …

I Poitras, M Bielmann, A Campeau-Lecours, C Mercier… - Sensors, 2019 - mdpi.com
Background: Workplace adaptation is the preferred method of intervention to diminish risk
factors associated with the development of work-related shoulder disorders. However, the …

Detection of freezing of gait using convolutional neural networks and data from lower limb motion sensors

B Shi, A Tay, WL Au, DML Tan… - IEEE Transactions on …, 2022 - ieeexplore.ieee.org
Parkinson's disease (PD) is a chronic, non-reversible neurodegenerative disorder, and
freezing of gait (FOG) is one of the most disabling symptoms in PD as it is often the leading …

Wearable sensor validation of sports-related movements for the lower extremity and trunk

KD Dahl, KM Dunford, SA Wilson, TL Turnbull… - Medical Engineering & …, 2020 - Elsevier
Abstract Inertial Measurement Units (IMUs), an alternative to 3D optical motion capture, are
growing in popularity to assess sports-related movements. This study validated an IMU …

An embedded, eight channel, noise canceling, wireless, wearable sEMG data acquisition system with adaptive muscle contraction detection

M Ergeneci, K Gokcesu, E Ertan… - IEEE transactions on …, 2017 - ieeexplore.ieee.org
Wearable technology has gained increasing popularity in the applications of healthcare,
sports science, and biomedical engineering in recent years. Because of its convenient …

Advanced rehabilitation technology in orthopaedics—a narrative review

Y Kuroda, M Young, H Shoman, A Punnoose… - International …, 2021 - Springer
Introduction As the demand for rehabilitation in orthopaedics increases, so too has the
development in advanced rehabilitation technology. However, to date, there are no review …

Measurement of ankle joint movements using IMUs during running

BH Kim, SH Hong, IW Oh, YW Lee, IH Kee, SY Lee - Sensors, 2021 - mdpi.com
Gait analysis has historically been implemented in laboratory settings only with expensive
instruments; yet, recently, efforts to develop and integrate wearable sensors into clinical …