Recommendations for the imaging assessment of prosthetic heart valves: a report from the European Association of Cardiovascular Imaging endorsed by the Chinese …

P Lancellotti, P Pibarot, J Chambers… - European Heart …, 2016 - academic.oup.com
Prosthetic heart valve (PHV) dysfunction is rare but potentially life-threatening. Although
often challenging, establishing the exact cause of PHV dysfunction is essential to determine …

Performance of cardiac cadmium-zinc-telluride gamma camera imaging in coronary artery disease: a review from the cardiovascular committee of the European …

D Agostini, PY Marie, S Ben-Haim, F Rouzet… - European journal of …, 2016 - Springer
The trade-off between resolution and count sensitivity dominates the performance of
standard gamma cameras and dictates the need for relatively high doses of radioactivity of …

Low dose in nuclear cardiology: state of the art in the era of new cadmium–zinc–telluride cameras

W Acampa, RR Buechel, A Gimelli - European Heart Journal …, 2016 - academic.oup.com
The use of myocardial perfusion imaging has seen a tremendous growth during the last
decade and has become the most commonly used non-invasive imaging tool for risk …

First assessment of simultaneous dual isotope (123I/99mTc) cardiac SPECT on two different CZT cameras: A phantom study

T Blaire, A Bailliez, F Ben Bouallegue… - Journal of Nuclear …, 2018 - Springer
Background We studied the impact of simultaneous dual-isotope acquisition on 123 I/99m
Tc mismatch assessment using two CZT cameras (DNM 530c, GE Healthcare and DSPECT …

Left ventricular function assessment using 2 different cadmium-zinc-telluride cameras compared with a γ-camera with cardiofocal collimators: dynamic cardiac …

A Bailliez, O Lairez, C Merlin, N Piriou… - Journal of Nuclear …, 2016 - Soc Nuclear Med
This study compared two SPECT cameras with cadmium-zinc-telluride (CZT) detectors to a
conventional Anger camera with cardiofocal collimators for the assessment of left ventricular …

First comparison of performances between the new whole-body cadmium–zinc–telluride SPECT-CT camera and a dedicated cardiac CZT camera for myocardial …

M Morelle, D Bellevre, C Hossein-Foucher… - Journal of Nuclear …, 2020 - Elsevier
Abstract Background Dedicated cardiac Cadmium–zinc–telluride (CZT) cameras show
superior performances compared with Anger systems, particularly in terms of spatial …

Myocardial perfusion imaging: Lessons learned and work to be done—update

AE Iskandrian, V Dilsizian, EV Garcia… - Journal of Nuclear …, 2018 - Elsevier
As the second term of our commitment to Journal begins, we, the editors, would like to reflect
on a few topics that have relevance today. These include prognostication and paradigm …

Comparison of CZT SPECT and conventional SPECT for assessment of contractile function, mechanical synchrony and myocardial scar in patients with heart failure

D Wu, Z Zhang, R Ma, F Guo, L Wang… - Journal of Nuclear …, 2019 - Elsevier
Aim The aim of this study was to compare CZT-SPECT (CZT SPECT) to conventional SPECT
(C-SPECT) in the assessment of left ventricular myocardial scar, contractile function, and …

Routine evaluation of left ventricular function using CZT-SPECT, with low injected activities and limited recording times

M Claudin, L Imbert, W Djaballah, N Veran… - Journal of Nuclear …, 2018 - Springer
Abstract Purpose Gamma-cameras, with Cadmium-Zinc-Telluride (CZT) detectors, allow to
perform myocardial perfusion imaging (MPI) with limited injected activities and recorded …

Pre-chemotherapy values for left and right ventricular volumes and ejection fraction by gated tomographic radionuclide angiography using a cadmium-zinc-telluride …

C Haarmark, C Haase, MM Jensen, B Zerahn - Journal of Nuclear …, 2016 - Elsevier
Background Estimation of left ventricular ejection fraction (LVEF) using equilibrium
radionuclide angiography is an established method for assessment of left ventricular …