Failures and leak inspection techniques of tube-to-tubesheet joints: A review

DT Thekkuden, AHI Mourad, AH Bouzid - Engineering Failure Analysis, 2021 - Elsevier
The integral components of heat exchangers and in particular the tubes, tubesheets and
tube-to-tubesheet joints have vital roles in the proper functioning of this equipment. Several …

A review of the crosswind effect on the natural draft cooling towers

X Li, H Gurgenci, Z Guan, X Wang, L Xia - Applied Thermal Engineering, 2019 - Elsevier
Crosswind is a significant concern for the design and operation of a natural draft cooling
tower. The negative effects of crosswind on the thermal performance of natural draft cooling …

Optimization of the circulating cooling water mass flow in indirect dry cooling system of thermal power unit using artificial neural network based on genetic algorithm

W Zhang, L Ma, B Jia, Z Zhang, Y Liu, L Duan - Applied Thermal …, 2023 - Elsevier
The power consumption of circulating pumps can be effectively reduced by optimizing the
circulating cooling water mass flow rate in indirect dry cooling system of a thermal power …

Anti-freezing mechanism of the direct air-cooled system by splitting columns operation

L Zhang, J Zhou, S Zuo, W Yuan, Q Zhang - … Communications in Heat and …, 2024 - Elsevier
In areas rich in coal but lacking water, thermal power plants, or nuclear power plants are
widely adopting direct air-cooled systems due to their excellent water-saving capabilities …

Entransy analysis optimization of cooling water flow distribution in a dry cooling tower of power plant under summer crosswinds

H Wei, T Wu, Z Ge, L Yang, X Du - Energy, 2019 - Elsevier
The performance of natural draft dry cooling tower (NDDCT) of a coal-fired power generating
unit is susceptible to ambient conditions, such as natural wind and temperature. An …

Energy efficient strategies for anti-freezing of air-cooled heat exchanger

Y Kong, W Wang, L Yang, X Du - Applied Energy, 2020 - Elsevier
In cold winter, the air-cooled heat exchanger of natural draft dry cooling system in thermal
power plants is easy to freeze, so the turbine back pressure is generally lifted to avoid …

Towards zero water consumption in solar tower power plants

C Marugán-Cruz, S Sánchez-Delgado… - Applied Thermal …, 2020 - Elsevier
Important efforts are dedicated to reduce water use in the power generation sector. In this
paper the use of a dry Heller cooling system is proposed to diminish the water consumption …

Synthesis cooling water system with air coolers

J Ma, Y Wang, X Feng, D Xu - Chemical Engineering Research and Design, 2018 - Elsevier
Adding air coolers to cooling water system is an effective way to reduce heat load and the
cost of cooling water system. It is also an effective method to prevent fouling and save water …

Freeze protection performance of natural draft wet cooling tower with different partition water distributions

W Yuan, S Zuo, J Zhou, Q Zhang, L Zhang - Applied Thermal Engineering, 2025 - Elsevier
With the construction of the deep peak regulation of thermal power units, the freezing risk of
cooling towers under low load conditions is aggravated. Therefore, in order to keep natural …

Utilization of partial through-flow tower shell to cope with the excess cooling capacity of dry cooling tower in extremely cold days with crosswind

H Ma, F Si, K Zhu, J Wang - International Journal of Thermal Sciences, 2019 - Elsevier
During low ambient temperature periods, the huge heat transfer temperature difference
would result in an excess cooling capacity of the natural draft dry cooling tower. So low …