Hemolysis testing in vitro: A review of challenges and potential improvements

K von Petersdorff-Campen, MS Daners - ASAIO journal, 2022 - journals.lww.com
Many medical devices such as cardiopulmonary bypass systems, mechanical heart valves,
or ventricular assist devices are intended to come into contact with blood flow during use. In …

[HTML][HTML] Impella 5.5 versus Centrimag: a head-to-head comparison of device hemocompatibility

Y Roka-Moiia, M Li, A Ivich, S Muslmani, KB Kern… - Asaio …, 2020 - journals.lww.com
Despite growing use of mechanical circulatory support, limitations remain related to
hemocompatibility. Here, we performed a head-to-head comparison of the …

Mechanical stress‐induced hemolysis of bovine blood is donor‐dependent

Z Li, J Hu, M Kamberi, RJ Rapoza - Artificial Organs, 2023 - Wiley Online Library
Introduction In vitro hemolysis testing is an essential method for assessing the hemolytic
potential of blood pumps, but has poor reproducibility. Further investigations are needed to …

A comprehensive comparison of the in vitro hemocompatibility of extracorporeal centrifugal blood pumps

P Li, X Mei, W Ge, T Wu, M Zhong, N Huan… - Frontiers in …, 2023 - frontiersin.org
Purpose: Blood damage has been associated with patients under temporary continuous-
flow mechanical circulatory support. To evaluate the side effects caused by transit blood …

Three‐dimensional membranes for artificial lungs: Comparison of flow‐induced hemolysis

F Hesselmann, D Arnemann, P Bongartz… - Artificial …, 2022 - Wiley Online Library
Background Membranes based on triply periodic minimal surfaces (TPMS) have proven a
superior gas transfer compared to the contemporary hollow fiber membrane (HFM) design in …

The Effect of Flow Field on the Initial Formation of Thrombus in Ventricular Assist Devices

K Meng, H Chen, X Zheng, Y Pan… - Advanced Materials …, 2024 - Wiley Online Library
Thrombosis is the main reason for the failure of ventricular assist devices (VADs). It has
been acknowledged that the platelet activation induced by the nonphysiological blood flow …

Blood–device interactions

MJ Simmonds, N Watanabe, AP McNamee… - … and respiratory support, 2025 - Elsevier
Management of heart and respiratory failure has improved in recent years in parallel with
advancements in pharmacological interventions and organ transplant. The advent of …

Effectiveness of Erythrocyte Morphology Observation as an Indicator for the Selection and Qualification of Blood in a Mechanically Induced Hemolysis Test

J Kim, T Kim, S Kim, J Eom, T Kim - Applied Sciences, 2024 - mdpi.com
Background: This study was conducted to confirm the reliability of an in vitro mechanically
induced hemolysis test (ISO 10993-4: 2017), which is essential for ensuring the safety of …

In vitro thrombogenicity evaluation of rotary blood pumps by thromboelastometry

M Klein, JC Tack, I Mager, J Maas… - Biomedical …, 2022 - degruyter.com
In vitro thrombogenicity tests for rotary blood pumps (RBPs) could benefit from assessing
coagulation kinematics, as RBP design improves. In this feasibility study, we investigated if …

Validation of a miniaturized test loop for the assessment of human blood damage by continuous-flow left-ventricular assist devices

E Woelke, I Mager, T Schmitz-Rode… - Annals of Biomedical …, 2021 - Springer
Despite improved hemocompatibility of left-ventricular assist devices (LVADs), assessment
of blood damage remains mandatory in preclinical testing as standardized by ASTM-F1841 …