Electrical impedance tomography: Tissue properties to image measures

A Adler, A Boyle - IEEE Transactions on Biomedical …, 2017 - ieeexplore.ieee.org
Electrical impedance tomography (EIT) uses electrical stimulation and measurement at the
body surface to image the electrical properties of internal tissues. It has the advantage of …

Electrical impedance tomography for artificial sensitive robotic skin: A review

D Silvera-Tawil, D Rye, M Soleimani… - IEEE Sensors …, 2014 - ieeexplore.ieee.org
Electrical impedance tomography (EIT) is a nondestructive imaging technique used to
estimate the internal conductivity distribution of a conductive domain by taking potential …

Uses and abuses of EIDORS: an extensible software base for EIT

A Adler, WRB Lionheart - Physiological measurement, 2006 - iopscience.iop.org
EIDORS is an open source software suite for image reconstruction in electrical impedance
tomography and diffuse optical tomography, designed to facilitate collaboration, testing and …

GREIT: a unified approach to 2D linear EIT reconstruction of lung images

A Adler, JH Arnold, R Bayford, A Borsic… - Physiological …, 2009 - iopscience.iop.org
Electrical impedance tomography (EIT) is an attractive method for clinically monitoring
patients during mechanical ventilation, because it can provide a non-invasive continuous …

Robust imaging using electrical impedance tomography: review of current tools

B Brazey, Y Haddab, N Zemiti - Proceedings of the …, 2022 - royalsocietypublishing.org
Electrical impedance tomography (EIT) is a medical imaging technique with many
advantages and great potential for development in the coming years. Currently, some …

Compensation of modelling errors due to unknown domain boundary in electrical impedance tomography

A Nissinen, VP Kolehmainen… - IEEE transactions on …, 2010 - ieeexplore.ieee.org
Electrical impedance tomography is a highly unstable problem with respect to measurement
and modeling errors. This instability is especially severe when absolute imaging is …

Interpretation of the modality of touch on an artificial arm covered with an EIT-based sensitive skin

D Silvera Tawil, D Rye… - The International Journal …, 2012 - journals.sagepub.com
During social interaction humans extract important information from tactile stimuli that can
improve their understanding of the interaction. The development of a similar capability in a …

Electrical impedance tomographic shape sensing for soft robots

W Xin, F Zhu, P Wang, Z Xie, Z Tang… - IEEE Robotics and …, 2023 - ieeexplore.ieee.org
With infinite degrees of freedom, soft robots are expected to achieve dexterous and complex
tasks, but this also puts forward higher requirements for their sensing capabilities. An …

Improved image reconstruction for an EIT-based sensitive skin with multiple internal electrodes

DS Tawil, D Rye, M Velonaki - IEEE Transactions on Robotics, 2011 - ieeexplore.ieee.org
Electrical impedance tomography (EIT) is a technique used to estimate the internal
conductivity of an electrically conductive body by using measurements made only at its …

Evaluation of electrical impedance tomography for determination of urinary bladder volume: comparison with standard ultrasound methods in healthy volunteers

D Leonhäuser, C Castelar, T Schlebusch… - Biomedical engineering …, 2018 - Springer
Background Continuous non-invasive urinary bladder volume measurement
(cystovolumetry) would allow better management of urinary tract disease. Electrical …