[HTML][HTML] High-power, short-duration radiofrequency ablation for the treatment of AF

ID Kotadia, SE Williams, M O'Neill - Arrhythmia & Electrophysiology …, 2019 - ncbi.nlm.nih.gov
Abstract High-power, short-duration (HPSD) ablation for the treatment of AF is emerging as
an alternative to ablation using conventional ablation generator settings characterised by …

Effects of electrode-tissue proximity on cardiac lesion formation using pulsed field ablation

B Howard, A Verma, WS Tzou, L Mattison… - Circulation …, 2022 - Am Heart Assoc
Background: Pulsed field ablation (PFA) is a novel energy modality for treatment of cardiac
arrhythmias. The impact of electrode-tissue proximity on lesion formation by PFA has not …

A Review of Recent Advancements in Sensor‐Integrated Medical Tools

J Park, B Seo, Y Jeong, I Park - Advanced Science, 2024 - Wiley Online Library
A medical tool is a general instrument intended for use in the prevention, diagnosis, and
treatment of diseases in humans or other animals. Nowadays, sensors are widely employed …

Novel measure of local impedance predicts catheter–tissue contact and lesion formation

MS Sulkin, JI Laughner, S Hilbert, S Kapa… - Circulation …, 2018 - Am Heart Assoc
Background: Coupling between the ablation catheter and myocardium is critical to resistively
heat tissue with radiofrequency ablation. The objective of this study was to evaluate whether …

High-power, low-flow, short-ablation duration—the key to avoid collateral injury?

F Ali-Ahmed, V Goyal, M Patel, F Orelaru… - Journal of Interventional …, 2019 - Springer
Background A common approach to ablating along the posterior wall of the left atrium in
atrial fibrillation ablation is to use low power with longer duration for durable lesions and …

Combined local impedance and contact force for radiofrequency ablation assessment

K Garrott, J Laughner, S Gutbrod, A Sugrue, A Shuros… - Heart rhythm, 2020 - Elsevier
Background The combination of contact force (CF) and local impedance (LI) may improve
tissue characterization and lesion prediction during radiofrequency (RF) ablation. Objective …

Rapid pacing and high‐frequency jet ventilation additively improve catheter stability during atrial fibrillation ablation

A Aizer, JK Qiu, AV Cheng, PB Wu… - Journal of …, 2020 - Wiley Online Library
Introduction Catheter stability during atrial fibrillation ablation is associated with higher
ablation success rates. Rapid cardiac pacing and high‐frequency jet ventilation (HFJV) …

[HTML][HTML] Real-time photoacoustic assessment of radiofrequency ablation lesion formation in the left atrium

S Iskander-Rizk, P Kruizinga, R Beurskens… - Photoacoustics, 2019 - Elsevier
In interventional electrophysiology, catheter-based radiofrequency (RF) ablation procedures
restore cardiac heart rhythm by interrupting aberrant conduction paths. Real-time feedback …

Cardiac mapping systems: rhythmia, topera, ensite precision, and CARTO

M Borlich, P Sommer - Cardiac Electrophysiology Clinics, 2019 - cardiacep.theclinics.com
The interventional therapy for cardiac arrhythmias is an irreplaceable part of modern
cardiological therapy. The development in the field of 3-D mapping systems and catheter …

Safety and efficacy of delivering high-power short-duration radiofrequency ablation lesions utilizing a novel temperature sensing technology

G Rozen, LM Ptaszek, I Zilberman, V Douglas… - EP …, 2018 - academic.oup.com
Aims Delivery of high-power short-duration radiofrequency (RF) ablation lesions is not
commonly used, in part because conventional thermocouple (TC) technology …