Management of periprosthetic femoral fractures following total hip arthroplasty: a review

MP Abdel, U Cottino, TM Mabry - International orthopaedics, 2015 - Springer
Purpose As the number of total hip arthroplasties (THAs) is increasing, the expected number
of periprosthetic femur fractures is also expected to increase. As such, a thorough grasp of …

Modular revision stems in total hip arthroplasty

RE Jones - Clinical Orthopaedics and Related Research®, 2004 - journals.lww.com
Many different clinical circumstances are seen in revision total hip arthroplasty. Modular
stems provide significant flexibility in choices to ensure distal and/or proximal unitary …

Periprosthetic femur fractures treated with modular fluted, tapered stems

MP Abdel, DG Lewallen, DJ Berry - Clinical Orthopaedics and Related …, 2014 - Springer
Background Treatment of periprosthetic femur fractures is challenging, and high failure and
complication rates have been reported in many series. The optimal techniques and implants …

Revision total hip arthroplasty using a fluted and tapered modular distal fixation stem with and without extended trochanteric osteotomy

YS Park, YW Moon, SJ Lim - The Journal of arthroplasty, 2007 - Elsevier
We reviewed 62 revision total hip arthroplasties performed using a fluted and tapered
modular distal fixation stem after a mean follow-up of 4.2 years. An extended trochanteric …

Revision total hip arthoplasty: factors associated with re-revision surgery

M Khatod, G Cafri, MCS Inacio, AL Schepps… - JBJS, 2015 - journals.lww.com
Background: The survivorship of implants after revision total hip arthroplasty and risk factors
associated with re-revision are not well defined. We evaluated the re-revision rate with use …

Mid term results with the curved modular tapered, fluted titanium Revitan stem in revision hip replacement

B Fink, K Urbansky, P Schuster - The Bone & Joint Journal, 2014 - boneandjoint.org.uk
We report our experience of revision total hip replacement (THR) using the Revitan curved
modular titanium fluted revision stem in patients with a full spectrum of proximal femoral …

Minimum 5-year follow-up of a cementless, modular, tapered stem in hip revision arthroplasty

RJ Weiss, MO Beckman, A Enocson… - The Journal of …, 2011 - Elsevier
Hip revision surgery with a cementless tapered femoral component can provide axial and
rotational stability in patients with compromised proximal bone stock. This study includes 90 …

Uncemented femoral revision arthroplasty using a modular tapered, fluted titanium stem: 5-to 16-year results of 163 cases

DC Wirtz, S Gravius, R Ascherl, M Thorweihe… - Acta …, 2014 - Taylor & Francis
Background and purpose—Due to the relative lack of reports on the medium-to long-term
clinical and radiographic results of modular femoral cementless revision, we conducted this …

A modular cementless stem vs. cemented long-stem prostheses in revision surgery of the hip: a population-based study from the Swedish Hip Arthroplasty Register

RJ Weiss, A Stark, J Kärrholm - Acta orthopaedica, 2011 - Taylor & Francis
Background and purpose Modular cementless revision prostheses are being used with
increasing frequency. In this paper, we review risk factors for the outcome of the Link MP …

Improved outcome in femoral revision arthroplasty with tapered fluted modular titanium stems

DS Garbuz, A Toms, BA Masri… - … and Related Research®, 2006 - journals.lww.com
Many techniques have been advanced to achieve reliable femoral stem fixation in revision
total hip arthroplasty. In a cross-sectional study, we compared quality of life in 220 patients …