An electrochemical method for the preparation of 63Ni source for the calibration of thermoluminescence dosimeter (TLD)

M Kumar, J Udhayakumar, SS Gandhi… - Applied Radiation and …, 2009 - Elsevier
A novel electrochemical approach for preparation of 63Ni sources for their application as
check-light source for the calibration of thermo luminescence dosimeters (TLD) is described …

On the application of electrochemical techniques for the preparation of 57Co source core, encapsulation and quality evaluation for radiometric assay of nuclear fuel …

A Dash, M Kumar, J Udhayakumar, SS Gandhi… - Radiochimica …, 2011 - degruyter.com
This paper describes an electrochemical method for the preparation of 57Co source to be
used in quality evaluation of nuclear fuel rods. The electrolytic cell, the experimental set up …

Development of a 125I source for its application in bone densitometry

SK Saxena, Y Kumar, KT Pillai, A Dash - Applied Radiation and Isotopes, 2012 - Elsevier
This paper describes a method for the preparation of 125I sources for their use in bone
densitometer. The process consists of preparation of silver pellets of size∼ 2.5 mm (ϕ)× 0.6 …

Preparation of spherical 57Co source for the calibration of intra-operative gamma probe

J Udhayakumar, M Kumar, SS Gandhi… - Applied Radiation and …, 2012 - Elsevier
This paper describes an electrochemical method for deposition of a thin layer of 57Co on the
outer surface of a copper sphere of 5mm diameter intended to be used as a point radioactive …

A novel method for the preparation of large-area 90Sr/90Y sources for the calibration of hand contamination monitors

M Kumar, SS Gandhi, R Chakravarty, J Nuwad… - Applied Radiation and …, 2013 - Elsevier
This paper describes a method for the preparation of large-area 90 Sr/90 Y polymer film
sources for the calibration of hand contamination monitors. The process consists of solvent …

Selective Area Chemical-Deposition Process: An Innovative and Facile Route to Prepare 147Pm Sources for Dust Monitors

M Kumar, R Shukla, SS Gandhi… - Industrial & …, 2012 - ACS Publications
The potential utility of selective area chemical-deposition technique in the preparation of 147
Pm source for the measurement of particulate emission in air was demonstrated. The …

An electrochemical technique for fabrication of Mn-54 sources towards characterization of gamma counting nuclear instruments

M Kumar, MK Dey, AK Satpati, R Shukla… - Applied Radiation and …, 2021 - Elsevier
Long lived sealed radioactive sources are used for the energy calibration and efficiency
determination of counting systems used in the nuclear sector. Using a sulphate bath, a facile …

Preparation of 57Co point sources for the performance evaluation of nuclear imaging instruments

SK Saxena, M Kumar, Y Kumar, J Udhayakumar… - Applied Radiation and …, 2013 - Elsevier
This paper describes the utility of electrodeposition method to prepare 57 Co point sources.
A description of the electrolytic cell, the process of 57 Co electrodeposition, encapsulation …

An electrochemical technique to prepare 55Fe source for the calibration of the X-ray detectors

M Kumar, SS Gandhi, J Udhayakumar, AK Satpati… - Radiochimica …, 2013 - degruyter.com
This paper describes an electrochemical method for the preparation of 55Fe sources,
utilized in the calibration of low energy X-ray detectors. In this process, electrodeposition of …

A novel and facile approach for the preparation of 133Ba source core, encapsulation and quality evaluation

M Kumar, SS Gandhi, J Nuwad, J Udhayakumar… - Radiochimica …, 2013 - degruyter.com
This paper describes a facile and effective method to prepare 133Ba source exploiting the
intrinsic properties of the anodized titanium to electro-deposit 133Ba from an aqueous …