Condition monitoring based on partial discharge diagnostics using machine learning methods: A comprehensive state-of-the-art review

S Lu, H Chai, A Sahoo, BT Phung - IEEE Transactions on …, 2020 - ieeexplore.ieee.org
This paper presents a state-of-the-art review on machine learning (ML) based intelligent
diagnostics that have been applied for partial discharge (PD) detection, localization, and …

[HTML][HTML] Review of medium-voltage switchgear fault detection in a condition-based monitoring system by using deep learning

YAM Alsumaidaee, CT Yaw, SP Koh, SK Tiong… - Energies, 2022 - mdpi.com
In power energy distribution networks, switchgear is considered critical equipment. This is
because the act of monitoring the operation and condition of switchgear, as well as …

[HTML][HTML] A Review on the Classification of Partial Discharges in Medium-Voltage Cables: Detection, Feature Extraction, Artificial Intelligence-Based Classification, and …

H Kumar, M Shafiq, K Kauhaniemi, M Elmusrati - Energies, 2024 - mdpi.com
Medium-voltage (MV) cables often experience a shortened lifespan attributed to insulation
breakdown resulting from accelerated aging and anomalous operational and environmental …

Method for the diagnosis of high-voltage dielectric elements during operation based on dynamic registration of electromagnetic radiation

D Ivanov, T Galieva, M Sadykov… - E3S Web of …, 2020 - e3s-conferences.org
Complex remote monitoring and the developed non-contact diagnostic device (NDD) allow
monitoring the technical condition and revealing the residual life of high-voltage dielectric …

[HTML][HTML] Лабораторный стенд для разработки метода и системы непрерывного бесконтактного неразрушающего контроля технического состояния …

ТГ Галиева, ДА Иванов, МФ Садыков… - Омский научный …, 2021 - cyberleninka.ru
Измерение частичных разрядов (ЧР) является общепринятым во всем мире методом
диагностики изоляции электрического оборудования. Сегодня тенденция заключается …

Fluorescent fiber-based identification of incipient discharges in liquid nitrogen

J Naveen, R Sarathi, B Srinivasan - Cryogenics, 2021 - Elsevier
Identification of incipient discharges is a major challenge in liquid nitrogenbased super-
conducting power apparatus. In the present study, a variety of fluorescent fibers with different …

Implementation of a Method for Monitoring High-Voltage Suspended Insulation Based on Electromagnetic Registration of Partial Discharge Signals

D Ivanov, M Sadykov, T Galieva - 2023 International Ural …, 2023 - ieeexplore.ieee.org
the insulation of electrical equipment mainly determines the long-term and cost-effective
operation of the electrical system. Therefore, the diagnosis of high-voltage dielectric …

Methods of Periodic Complex Remote Measurement of Partial Discharge Characteristics in Highvoltage Insulators

D Ivanov, A Golenishchev-Kutuzov… - 2022 International Ural …, 2022 - ieeexplore.ieee.org
Diagnostics of the state of high voltage insulators is an important direction in the electric
power industry. In the last twenty years, a method for determining the technical condition of …

Research on PD source successive approximation positioning method based on multi sample information

Q Zhu, W Zhu, Z Gao, M Zhu - Journal of Physics: Conference …, 2021 - iopscience.iop.org
Abstract Ultra High Frequency (UHF) detection technology is widely used in Partial
Discharge (PD) detection and positioning of electrical equipment. However, how to achieve …

ОМСКИЙ НАУЧНЫЙ ВЕСТНИК

ТГ ГАЛИЕВА, ДА ИВАНОВ, МФ САДЫКОВ… - ОМСКИЙ НАУЧНЫЙ … - elibrary.ru
Измерение частичных разрядов (ЧР) является общепринятым во всем мире методом
диагностики изоляции электрического оборудования. Сегодня тенденция заключается …