Clinical performance of highly cross-linked polyethylenes in total hip arthroplasty

CA Jacobs, CP Christensen, AS Greenwald… - JBJS, 2007 - journals.lww.com
Clinical Performance of Highly Cross-Linked Polyethylenes in... : JBJS Clinical Performance of
Highly Cross-Linked Polyethylenes in Total Hip Arthroplasty : JBJS JBJS Journal Case …

Radiographic methods for the assessment of polyethylene wear after total hip arthroplasty

RW McCalden, DD Naudie, X Yuan, RB Bourne - JBJS, 2005 - journals.lww.com
All wear-measurement techniques assess femoral head penetration and therefore cannot
distinguish between true polyethylene wear and bedding-in. Multiple wear measurements …

Wear rate of highly cross-linked polyethylene in total hip arthroplasty: a randomized controlled trial

RW McCalden, SJ MacDonald, CH Rorabeck… - JBJS, 2009 - journals.lww.com
Background: Highly cross-linked polyethylene was introduced for clinical use in total hip
arthroplasty with the expectation that it would exhibit less wear when compared with …

Wear and osteolysis of highly crosslinked polyethylene at 10 to 14 years: the effect of femoral head size

PF Lachiewicz, ES Soileau… - Clinical Orthopaedics and …, 2016 - journals.lww.com
Background Highly crosslinked polyethylene (XLPE) was introduced to decrease
periprosthetic osteolysis related to polyethylene wear, a major reason for revision of total hip …

In vivo comparative wear study of traditional and highly cross-linked polyethylene in total hip arthroplasty

DW Manning, PP Chiang, JM Martell, JO Galante… - The Journal of …, 2005 - Elsevier
In this study, we compare the in vivo wear performance of electron beam–irradiated,
postirradiation-melted, highly cross-linked polyethylene (HXLPE) and traditional UHMWPE …

Femoral head size and wear of highly cross-linked polyethylene at 5 to 8 years

PF Lachiewicz, DS Heckman, ES Soileau… - … and Related Research®, 2009 - Springer
Wear of highly cross-linked polyethylene is reportedly independent of head size. To confirm
that observation we asked in our population whether head size related to wear with one type …

The creep and wear of highly cross-linked polyethylene: a three-year randomised, controlled trial using radiostereometric analysis

S Glyn-Jones, P McLardy-Smith, HS Gill… - The Journal of Bone …, 2008 - boneandjoint.org.uk
The creep and wear behaviour of highly cross-linked polyethylene and standard
polyethylene liners were examined in a prospective, double-blind randomised, controlled …

Five-year experience with Crossfire® highly cross-linked polyethylene

JA D'Antonio, MT Manley, WN Capello… - Clinical Orthopaedics …, 2005 - journals.lww.com
Our purpose was to compare the clinical wear performance of highly cross-linked
(Crossfire®) polyethylene with conventional (N2Vac™) polyethylene total hip bearings. We …

The incidence of acetabular osteolysis in young patients with conventional versus highly crosslinked polyethylene

NA Mall, RM Nunley, JJ Zhu, WJ Maloney… - … and Related Research®, 2011 - Springer
Background Osteolysis is a major mode of hip implant failure. Previous literature has
focused on the amount of polyethylene wear comparing highly crosslinked polyethylene …

Does fluoroscopy improve acetabular component placement in total hip arthroplasty?

BS Beamer, JH Morgan, C Barr, MJ Weaver… - … and Related Research®, 2014 - Springer
Background The success of THA largely depends on correct placement of the individual
components. Traditionally, these have been placed freehand using anatomic landmarks, but …