[HTML][HTML] Neointimal fibrotic lead encapsulation–Clinical challenges and demands for implantable cardiac electronic devices

J Keiler, M Schulze, M Sombetzki, T Heller, T Tischer… - Journal of …, 2017 - Elsevier
Every tenth patient with a cardiac pacemaker or implantable cardioverter-defibrillator
implanted is expected to have at least one lead problem in his lifetime. However …

Left bundle branch pacing better preserves ventricular mechanical synchrony than right ventricular pacing: a two-centre study

Y Mao, J Duchenne, Y Yang, C Garweg… - European Heart …, 2024 - academic.oup.com
Aims Left bundle branch pacing (LBBP) has been shown to better maintain electrical
synchrony compared with right ventricular pacing (RVP), but little is known about its impact …

A study of major and minor complications of 1500 transvenous lead extraction procedures performed with optimal safety at two high-volume referral centers

Ł Tułecki, A Polewczyk, W Jacheć… - International journal of …, 2021 - mdpi.com
Background: Transvenous lead extraction (TLE) is the preferred management strategy for
complications related to cardiac implantable electronic devices. TLE sometimes can cause …

Early, delayed and late cardiac implantable electronic device infections: do the timing of onset and pathogens matter?

A Polewczyk, W Jacheć, M Polewczyk… - Journal of Clinical …, 2022 - mdpi.com
Infections involving cardiac implantable electronic devices (CIEDs) occur at different times
after device-related procedures. The aim of this study was to investigate the timing of onset …

To abandon or not to abandon: late consequences of pacing and ICD lead abandonment

W Jacheć, A Polewczyk, L Segreti… - Pacing and Clinical …, 2019 - Wiley Online Library
Introduction The increasing number of cardiac implantable electronic device complications
represents a current problem. Abandoned leads are difficult to manage, even because …

Echocardiographic findings in patients with cardiac implantable electronic devices—analysis of factors predisposing to lead‐associated changes

D Nowosielecka, A Polewczyk… - Clinical Physiology …, 2021 - Wiley Online Library
Background The constant interaction between intracardiac leads and the heart and veins
results in excessive accumulation of fibrous connective tissue around the leads. The extent …

[HTML][HTML] Tissues attached to retrieved leadless pacemakers: histopathological evaluation of tissue composition in relation to implantation time and complications

KTN Breeman, R du Long, NEG Beurskens… - Heart Rhythm, 2021 - Elsevier
Background Leadless pacemakers (LPs) have proven safe and effective, but device
revisions remain necessary. Either replacing the LP or implanting a new adjacent LP is …

A novel clinical perspective on new masses after lead extraction (ghosts) by means of intracardiac echocardiography

C Caiati, G Luzzi, P Pollice, S Favale… - Journal of Clinical …, 2020 - mdpi.com
Background: A lead-reactive fibrous capsule (FC) identified by ultrasounds as an atrial or
ventricular lead thickness of more than 1 mm above the vendor-declared lead diameter (TL) …

Quantitative and qualitative assessment of adhesive thrombo-fibrotic lead encapsulations (TFLE) of pacemaker and ICD leads in arrhythmia patients—a post mortem …

J Keiler, M Schulze, R Dreger, A Springer… - Frontiers in …, 2020 - frontiersin.org
The demand for cardiac implantable electronic devices for arrhythmia therapy is still
unabated and rising. Despite onward optimizations, lead-related problems such as …

Lead‐dependent infective endocarditis: the role of factors predisposing to its development in an analysis of 414 clinical cases

A Polewczyk, W Jacheć, M Janion… - Pacing and Clinical …, 2015 - Wiley Online Library
Background Lead‐dependent infective endocarditis (LDIE) is a serious and insidious
infective disease spreading along the leads to valve leaflets and endocardial surface. LDIE …