Importance of cochlear health for implant function

BE Pfingst, N Zhou, DJ Colesa, MM Watts, SB Strahl… - Hearing research, 2015 - Elsevier
Amazing progress has been made in providing useful hearing to hearing-impaired
individuals using cochlear implants, but challenges remain. One such challenge is …

Probing the electrode-neuron interface with focused cochlear implant stimulation

J Arenberg Bierer - Trends in amplification, 2010 - journals.sagepub.com
Cochlear implants are highly successful neural prostheses for persons with severe or
profound hearing loss who gain little benefit from hearing aid amplification. Although …

Examining the electro-neural interface of cochlear implant users using psychophysics, CT scans, and speech understanding

CJ Long, TA Holden, GH McClelland… - Journal of the …, 2014 - Springer
This study examines the relationship between focused-stimulation thresholds, electrode
positions, and speech understanding in deaf subjects treated with a cochlear implant (CI) …

Assessing the electrode-neuron interface with the electrically evoked compound action potential, electrode position, and behavioral thresholds

L DeVries, R Scheperle, JA Bierer - … of the Association for Research in …, 2016 - Springer
Variability in speech perception scores among cochlear implant listeners may largely reflect
the variable efficacy of implant electrodes to convey stimulus information to the auditory …

Processing F0 with cochlear implants: Modulation frequency discrimination and speech intonation recognition

M Chatterjee, SC Peng - Hearing research, 2008 - Elsevier
Fundamental frequency (F0) processing by cochlear implant (CI) listeners was measured
using a psychophysical task and a speech intonation recognition task. Listeners' Weber …

Threshold and channel interaction in cochlear implant users: evaluation of the tripolar electrode configuration

JA Bierer - The Journal of the Acoustical Society of America, 2007 - pubs.aip.org
The efficacy of cochlear implants is limited by spatial and temporal interactions among
channels. This study explores the spatially restricted tripolar electrode configuration and …

Identifying cochlear implant channels with poor electrode-neuron interface: partial tripolar, single-channel thresholds and psychophysical tuning curves

JA Bierer, KF Faulkner - Ear and hearing, 2010 - journals.lww.com
Objective: The goal of this study was to evaluate the ability of a threshold measure, made
with a restricted electrode configuration, to identify channels exhibiting relatively poor spatial …

Reducing channel interaction through cochlear implant programming may improve speech perception: Current focusing and channel deactivation

JA Bierer, L Litvak - Trends in hearing, 2016 - journals.sagepub.com
Speech perception among cochlear implant (CI) listeners is highly variable. High degrees of
channel interaction are associated with poorer speech understanding. Two methods for …

Effects of electrode location on estimates of neural health in humans with cochlear implants

KC Schvartz-Leyzac, TA Holden, TA Zwolan… - Journal of the …, 2020 - Springer
There are a number of psychophysical and electrophysiological measures that are
correlated with SGN density in animal models, and these same measures can be performed …

Long‐term influence of electrode array length on speech recognition in cochlear implant users

MW Canfarotta, MT Dillon, CA Buchman… - The …, 2021 - Wiley Online Library
Objectives/Hypothesis Results from a prospective trial demonstrated better speech
recognition for cochlear implant (CI) recipients implanted with a long lateral wall electrode …